Contactor, Type S, multipole lighting, electrically held, 60A, 3 pole, 277 VAC 60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, electrically held, 60A, 3 pole, 277 VAC 60 Hz coil, NEMA 12
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 10 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 208 VAC coil, NEMA 3R
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 10 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 208 VAC coil, NEMA 3R
Direct rotary handle, TeSys GV7, black, padlockable, IP40
Direct rotary handle, TeSys GV7, black, padlockable, IP40
Contactor, Definite Purpose, 50A, 3 pole, 30 HP at 575 VAC, 3 phase, 110/120 VAC 50/60 Hz coil, with 2 mounting screws
Contactor, Definite Purpose, 50A, 3 pole, 30 HP at 575 VAC, 3 phase, 110/120 VAC 50/60 Hz coil, with 2 mounting screws
TeSys LRD thermal overload relays – 1.6…2.5 A – class 20
TeSys LRD thermal overload relays - 1.6...2.5 A - class 20
Switch, manual, 20A, 2 pole, 3 HP at 575 VAC, single phase, toggle operated, no indicator, NEMA 7&9, one conduit opening
Switch, manual, 20A, 2 pole, 3 HP at 575 VAC, single phase, toggle operated, no indicator, NEMA 7&9, one conduit opening
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 3 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 3 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
COMBO STARTER 600VAC 27A NEMA
COMBO STARTER 600VAC 27A NEMA
IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 65A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VDC coil, open style
NEMA motor starter, Type S, nonreversing, Size 1, 27A, 10HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 240VAC coil, NEMA 1
NEMA motor starter, Type S, nonreversing, Size 1, 27A, 10HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 240VAC coil, NEMA 1
soft starter for asynchronous motor, Altistart 22, control 110V, 208V, 75hp
soft starter for asynchronous motor, Altistart 22, control 110V, 208V, 75hp
NEMA motor starter, Type S, nonreversing, Size 2, 45A, 25HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 240VAC coil, open
NEMA motor starter, Type S, nonreversing, Size 2, 45A, 25HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 240VAC coil, open
Contactor, Type L, multipole lighting, electrically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, electrically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 115VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 115VAC 50/60Hz coil, open
NEMA Contactor and NEMA Motor Starter, Type S, replacement contact kit, 8502SB, 8536SB, NEMA size 0, 3 pole
NEMA Contactor and NEMA Motor Starter, Type S, replacement contact kit, 8502SB, 8536SB, NEMA size 0, 3 pole
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC, 230 to 240VAC coil
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC, 230 to 240VAC coil
NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 1 HP at 230 VAC, 5 kA SSCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 1 HP at 230 VAC, 5 kA SSCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 10 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 10 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 1
TeSys GB2 thermal magnetic circuit protector, 1 P, 2 A, Id = 26 A
TeSys GB2 thermal magnetic circuit protector, 1 P, 2 A, Id = 26 A
Contactor, Definite Purpose, 30A, 2 pole, 5HP at 230VAC, 1 phase, 208/240VAC 60Hz 220VAC 50Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 5HP at 230VAC, 1 phase, 208/240VAC 60Hz 220VAC 50Hz coil, open
soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 500V, 18.5 to 45kW
soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 500V, 18.5 to 45kW
IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 4 NO, 240VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 4 NO, 240VAC 50/60Hz coil, open style
lighting contactor, mechanically held, 100 A, 4 pole, NEMA 1, 120/110V 60/50Hz
lighting contactor, mechanically held, 100 A, 4 pole, NEMA 1, 120/110V 60/50Hz
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VDC coil, open style
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, 600 V fuse, 110/120 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, 600 V fuse, 110/120 VAC 50/60 Hz coil, NEMA 1
NEMA starter, Type S, reversing, horizontal, Size 00, 9A, 2HP at 575VAC, 5kA SCCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, horizontal, Size 00, 9A, 2HP at 575VAC, 5kA SCCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 220 to 230VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 220 to 230VAC coil
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 10 HP at 460 VAC, up to 65 kA SCCR, 3 phase, 3 pole, bimetal, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 10 HP at 460 VAC, up to 65 kA SCCR, 3 phase, 3 pole, bimetal, 240 VAC coil, NEMA 1
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NC, 24VDC coil
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NC, 24VDC coil
IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 400VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 400VAC 50/60Hz coil, open
lighting contactor, electrically held, 30 A, 3 pole, NEMA 1, 277V 60Hz
lighting contactor, electrically held, 30 A, 3 pole, NEMA 1, 277V 60Hz
TeSys F – main contact set – 3P
TeSys F - main contact set - 3P
NEMA Starter, Type S, reversing, vertical, Size 0, 18A, 5 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 240 VAC coil, open
NEMA Starter, Type S, reversing, vertical, Size 0, 18A, 5 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 240 VAC coil, open
NEMA motor starter, Type S, nonreversing, Size 0, 18A, 5HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 480VAC coil, NEMA 1
NEMA motor starter, Type S, nonreversing, Size 0, 18A, 5HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 480VAC coil, NEMA 1
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 208 V AC 50/60 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 208 V AC 50/60 Hz coil
Contactor, Definite Purpose, 40A, 1 pole, 24/24VAC 50/60Hz coil, open
Contactor, Definite Purpose, 40A, 1 pole, 24/24VAC 50/60Hz coil, open
Suppressor module, TeSys Deca, bidirectional peak limiting diode, 72VDC
Suppressor module, TeSys Deca, bidirectional peak limiting diode, 72VDC
soft starter for asynchronous motor, Altistart 01, ATS01, 25A, 110 to 480V, 2.2 to 11kW
soft starter for asynchronous motor, Altistart 01, ATS01, 25A, 110 to 480V, 2.2 to 11kW
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 24 V AC 50/60 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 24 V AC 50/60 Hz coil
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 1
8903LX mechanically held lighting contactor, 3 P, 3 NO, 30 A, 600 V, 110/120 V 50/60 Hz coil, NEMA 3R/12
8903LX mechanically held lighting contactor, 3 P, 3 NO, 30 A, 600 V, 110/120 V 50/60 Hz coil, NEMA 3R/12
TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 50 A – 48 V DC standard coil
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 48 V DC standard coil
Reversing Contactor, Size 00, 2-Pole, Horizontal Open Style
Reversing Contactor, Size 00, 2-Pole, Horizontal Open Style
Non-Reversing Starter Size 1P, 2-Pole, Melting Alloy Overload, Nema 1 +Options
Non-Reversing Starter Size 1P, 2-Pole, Melting Alloy Overload, Nema 1 +Options
TeSys D – safety protective cover – for LC1 D115…150
TeSys D - safety protective cover - for LC1 D115...150
TeSys F – contactor coil – LX1FG – 380…400V AC 50 Hz – 460…480 V AC 60 Hz
TeSys F - contactor coil - LX1FG - 380...400V AC 50 Hz - 460...480 V AC 60 Hz
TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A – 24 V DC coil
TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V DC coil
TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 38 A – 24 V DC coil
TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 38 A - 24 V DC coil
Suppressor module, TeSys Deca, RC circuit, 110 to 240VAC
Suppressor module, TeSys Deca, RC circuit, 110 to 240VAC
lighting contactor, electrically held, 200 A, 3 pole, NEMA 1, 277V 60Hz
lighting contactor, electrically held, 200 A, 3 pole, NEMA 1, 277V 60Hz
IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 120VAC 50/60Hz coil, open style
NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 2 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 277 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 2 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 277 VAC coil, NEMA 1
soft starter for asynchronous motor, Altistart 01, ATS01, 9A, 110 to 480V, 1.1 to 4kW
soft starter for asynchronous motor, Altistart 01, ATS01, 9A, 110 to 480V, 1.1 to 4kW
NEMA motor starter, Type S, nonreversing, Size 1, 27A, 10HP at 460VAC, 5kA SCCR, 3 phase, 3 pole, melting alloy, 120VAC coil, open
NEMA motor starter, Type S, nonreversing, Size 1, 27A, 10HP at 460VAC, 5kA SCCR, 3 phase, 3 pole, melting alloy, 120VAC coil, open
TeSys Deca Manual Starter and Protector, thermal magnetic circuit protector, push buttons, 9…14 A, spring terminals
TeSys Deca Manual Starter and Protector, thermal magnetic circuit protector, push buttons, 9...14 A, spring terminals
Ultra compact starter, TeSys Hybrid, 3P, 500VAC, 3kW at 400V, 24VDC
Ultra compact starter, TeSys Hybrid, 3P, 500VAC, 3kW at 400V, 24VDC
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 3 pole, 110/120 VAC 50/60 Hz coil, melting alloy overload, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 3 pole, 110/120 VAC 50/60 Hz coil, melting alloy overload, NEMA 1
Kit for assembling star delta starters, for 3 x contactors LC1D09-D18 with circuit breaker GV2, compact mounting
Kit for assembling star delta starters, for 3 x contactors LC1D09-D18 with circuit breaker GV2, compact mounting
Contactor, Type L, multipole lighting, electrically held, 30A, 6 pole, 600 V, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type L, multipole lighting, electrically held, 30A, 6 pole, 600 V, 440/480 VAC 50/60 Hz coil, NEMA 1
NEMA Combination Starter, Type S, 60A fusible disconnect, Size 1, 27A, 7.5 HP at 240 VAC polyphase, 24 VAC coil, NEMA 1
NEMA Combination Starter, Type S, 60A fusible disconnect, Size 1, 27A, 7.5 HP at 240 VAC polyphase, 24 VAC coil, NEMA 1