Circuit breaker, PowerPacT B, 45A, 2 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT B, 45A, 2 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 100A, 2 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, AB
Circuit breaker, PowerPacT H, 100A, 2 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, AB
NEMA Combination Starter, Type S, 30A fusible disconnect, Size 1, 27A, 10 HP at 600 VAC polyphase, 120 VAC coil, NEMA 1
NEMA Combination Starter, Type S, 30A fusible disconnect, Size 1, 27A, 10 HP at 600 VAC polyphase, 120 VAC coil, NEMA 1
NEMA Control Relay, Type X, pneumatic timer attachment, one minute on delay, 10A resistive at 600 VAC, 1 NO and 1 NC, ring tongue
NEMA Control Relay, Type X, pneumatic timer attachment, one minute on delay, 10A resistive at 600 VAC, 1 NO and 1 NC, ring tongue
line choke – 2 mH – 18 A – 1 phase – 30 W – for variable speed drive
line choke - 2 mH - 18 A - 1 phase - 30 W - for variable speed drive
Multi 9 – C60 UL1077 – MCB – 4P – 4 A – D Curve – 480Y/277 V – 5 kA
Multi 9 - C60 UL1077 - MCB - 4P - 4 A - D Curve - 480Y/277 V - 5 kA
MN undervoltage release – 24 V AC – 200/250 V DC – for MTZ drawout
MN undervoltage release - 24 V AC - 200/250 V DC - for MTZ drawout
NQ Panelboard Serv Entr 300A, 1 Phase, 84 CCT, Main Breaker, Surface Trim
NQ Panelboard Serv Entr 300A, 1 Phase, 84 CCT, Main Breaker, Surface Trim
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 125 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 125 V DC standard coil
NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 2 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 2 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 1
One asymmetric mounting rail 32×15 L 1200mm Supply: 20
One asymmetric mounting rail 32x15 L 1200mm Supply: 20
Flash Disk SSD 240 GB Blank with 5 years manufacturer warranty
Flash Disk SSD 240 GB Blank with 5 years manufacturer warranty
COMBO STARTER 600VAC 27A NEMA
COMBO STARTER 600VAC 27A NEMA
TRANSFORMER CURRENT 600:5
TRANSFORMER CURRENT 600:5
Circuit breaker, PowerPacT P, 1000A, 3 pole, 480VAC, 100kA, I-Line, ET1.0l, 80%, ABC
Circuit breaker, PowerPacT P, 1000A, 3 pole, 480VAC, 100kA, I-Line, ET1.0l, 80%, ABC
Mini CB, QO, 20 A, 1P, 120 V, 22 kA, Bolt on, GFI, Aux Switch 1A
Mini CB, QO, 20 A, 1P, 120 V, 22 kA, Bolt on, GFI, Aux Switch 1A
Spacial CRN plain door w/o mount.plate. H400xW600xD300 IP66 IK10 RAL7035..
Spacial CRN plain door w/o mount.plate. H400xW600xD300 IP66 IK10 RAL7035..
NQ Panelboard Acc. Branch Deadfront Kit 400A, 1 Phase, 72 CCT
NQ Panelboard Acc. Branch Deadfront Kit 400A, 1 Phase, 72 CCT
TeSys K reversing contactor – 3P – AC-3 <= 440 V 6 A – 1 NO – 220…230 VAC coil
TeSys K reversing contactor - 3P - AC-3 <= 440 V 6 A - 1 NO - 220...230 VAC coil
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Hand IP69K w/o Heating, Long Sensing Range, Hp = 610 mm, R=30 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Hand IP69K w/o Heating, Long Sensing Range, Hp = 610 mm, R=30 mm
Limit switch, Limit switches XC Standard, XCKL, metal end plunger, 1NC+1 NO, slow break, Cable gland
Limit switch, Limit switches XC Standard, XCKL, metal end plunger, 1NC+1 NO, slow break, Cable gland
TeSys K – non differential thermal overload relays – 1.2…1.8 A – class 10A
TeSys K - non differential thermal overload relays - 1.2...1.8 A - class 10A
TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 40 A – 415 V AC 50/60 Hz coil
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 415 V AC 50/60 Hz coil
servo motor BSH, Lexium 05, 7.8N.m, 2500rpm, 100mm, keyed shaft, Sincos single turn, with brake, IP50, straight
servo motor BSH, Lexium 05, 7.8N.m, 2500rpm, 100mm, keyed shaft, Sincos single turn, with brake, IP50, straight
integrated drive ILA with servo motor – 24..48 V – DeviceNet – PCB connector
integrated drive ILA with servo motor - 24..48 V - DeviceNet - PCB connector
Protective rear cover, Harmony XAP, for plastron XAPE304, insulated material, without opening, IP 65
Protective rear cover, Harmony XAP, for plastron XAPE304, insulated material, without opening, IP 65
Pre wired connectors XZ, straight female, M12, 4 pins, cable PVC 2 m
Pre wired connectors XZ, straight female, M12, 4 pins, cable PVC 2 m
Head for illuminated selector switch, Harmony XB4, metal, green handle, 22mm, universal LED, 2 positions, stay put
Head for illuminated selector switch, Harmony XB4, metal, green handle, 22mm, universal LED, 2 positions, stay put
Head for selector switch, Harmony XB6, black square Ø 16 3 position spring return
Head for selector switch, Harmony XB6, black square Ø 16 3 position spring return
Panelboard accessory, NF, deadfront kit, subfeed breaker, 400A, LA/J frame
Panelboard accessory, NF, deadfront kit, subfeed breaker, 400A, LA/J frame
Standard undervoltage release MN, ComPacT NSXm, 440/480VAC 60Hz
Standard undervoltage release MN, ComPacT NSXm, 440/480VAC 60Hz
Circuit breaker, PowerPacT B, 125A, 4 pole, 600Y/347VAC, 14kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 125A, 4 pole, 600Y/347VAC, 14kA, terminal nut, thermal magnetic, 80%
TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 65 A – 690 V AC 50/60 Hz coil
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 690 V AC 50/60 Hz coil
Limit switch, 9007MS, miniature, cross roller plunger, 10A at 240VAC, 1NO/1NC, 9 feet of cable, side, NEMA 4, 6P, 12, 13
Limit switch, 9007MS, miniature, cross roller plunger, 10A at 240VAC, 1NO/1NC, 9 feet of cable, side, NEMA 4, 6P, 12, 13
soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 440V, 18.5 to 37kW
soft starter for asynchronous motor, Altistart 22, control 230V, 230 to 440V, 18.5 to 37kW
Unit substation, Mini Power-Zone, bolt on, 30kVA, 3 phase, 480V primary, 208Y/120V secondary, 65kA, CC
Unit substation, Mini Power-Zone, bolt on, 30kVA, 3 phase, 480V primary, 208Y/120V secondary, 65kA, CC
Busway Circuit Breaker Plug-in Unit 30A 480Y/277V 5B 3FT CORD L21-30 W/METER
Busway Circuit Breaker Plug-in Unit 30A 480Y/277V 5B 3FT CORD L21-30 W/METER
Pump Panel, NEMA Type S, Well Guard, oil field, Size 4, 135A, 100 HP, 200A fusible disconnect, Motor Logic SSOLR, 440/480 VAC 50/60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, oil field, Size 4, 135A, 100 HP, 200A fusible disconnect, Motor Logic SSOLR, 440/480 VAC 50/60 Hz coil, NEMA 3R
Power distribution block, Linergy, 1 pole, 1 line, 4 load, 115A Cu, 90A Al, 600V
Power distribution block, Linergy, 1 pole, 1 line, 4 load, 115A Cu, 90A Al, 600V
Selector switch head, Harmony 9001SK, plastic, standard handle, black, 30mm, 3 positions, spring return right to center
Selector switch head, Harmony 9001SK, plastic, standard handle, black, 30mm, 3 positions, spring return right to center
Insertable nuts M3. Supply: 50 units
Insertable nuts M3. Supply: 50 units
Lighting Contactor Oversized Enclosure – 8903L/S – NEMA 12/3R
Lighting Contactor Oversized Enclosure - 8903L/S - NEMA 12/3R
portal axis PAS E – profile size 80x80mm – toothed belt – ball – stroke 400mm
portal axis PAS E - profile size 80x80mm - toothed belt - ball - stroke 400mm
Heavy load cross rails, PanelSeT SFN, Spacial SF, W800mm, set of 2
Heavy load cross rails, PanelSeT SFN, Spacial SF, W800mm, set of 2
Mini circuit breaker accessory, Homeline, circuit breaker retaining kit
Mini circuit breaker accessory, Homeline, circuit breaker retaining kit
thermal overload relays, TeSys Deca, 60…100A, class 20
thermal overload relays, TeSys Deca, 60...100A, class 20
Telemecanique Safety switches XCS, M16 x 1.5 adaptor, for plastic switch XCSPA
Telemecanique Safety switches XCS, M16 x 1.5 adaptor, for plastic switch XCSPA
integrated drive ILS with stepper motor – 24..36 V – CANopen DS301 – 5 A
integrated drive ILS with stepper motor - 24..36 V - CANopen DS301 - 5 A
QOU Miniature Circuit Breaker, 20A, 2P, 240V, 10kA, Aux Switch
QOU Miniature Circuit Breaker, 20A, 2P, 240V, 10kA, Aux Switch
NF Panelboard Acc. Compression Lug Kit 600A, Aluminum
NF Panelboard Acc. Compression Lug Kit 600A, Aluminum
Gen Panel, QO, Split Bus, 200A, NEMA 1, PON
Gen Panel, QO, Split Bus, 200A, NEMA 1, PON
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 40A, C curve, 10kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 40A, C curve, 10kA (UL489), 10kA (IEC/EN 60947-2)
Pump or compressor switch 9013GS – adjustable diff. – 40-60 psi
Pump or compressor switch 9013GS - adjustable diff. - 40-60 psi
Front & rear plinth, PanelSeT SFN, Spacial SF, for electrical enclosure W300mm, plinth H200mm
Front & rear plinth, PanelSeT SFN, Spacial SF, for electrical enclosure W300mm, plinth H200mm
Photoelectric sensors XU, XUY, ampli for fibre, plastic, 12…24 VDC, M8
Photoelectric sensors XU, XUY, ampli for fibre, plastic, 12...24 VDC, M8
TeSys K contactor – 3P – AC-3 <= 440 V 6 A – 1 NC aux. – 24 V AC coil
TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V AC coil
Head for illuminated push button, Harmony XB6, flush pushbutton Ø 16 latching with 6 coloured caps
Head for illuminated push button, Harmony XB6, flush pushbutton Ø 16 latching with 6 coloured caps
Circuit breaker accessory, PowerPacT J, lug kit, mechanical, terminal, control wire, qty 2
Circuit breaker accessory, PowerPacT J, lug kit, mechanical, terminal, control wire, qty 2
Modicon M340 automation platform, RS 232 serial link cable, for data terminal equipment, 3 m
Modicon M340 automation platform, RS 232 serial link cable, for data terminal equipment, 3 m