ClimaSys standard cooling unit side of enclosure – 380W at 230 V
ClimaSys standard cooling unit side of enclosure - 380W at 230 V
power cable- between servomotor BSH and servodrive – 4 x 10 mm² + 2 x 1 mm² -15m
power cable- between servomotor BSH and servodrive - 4 x 10 mm² + 2 x 1 mm² -15m
Mini circuit breaker, Homeline, 15A, 1 pole, 120/240VAC, 10kA AIR, standard type, plug in, UL
Mini circuit breaker, Homeline, 15A, 1 pole, 120/240VAC, 10kA AIR, standard type, plug in, UL
Panelboard accessory, NF, vertical wireway, MH, 14in
Panelboard accessory, NF, vertical wireway, MH, 14in
CANopen bus daisy chain cable – straight – M12-A male-female – 2m
CANopen bus daisy chain cable - straight - M12-A male-female - 2m
Trim front, I-Line Panelboard, HCP, surface mount, 4 pcs, 42in W x 50in H
Trim front, I-Line Panelboard, HCP, surface mount, 4 pcs, 42in W x 50in H
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 10 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 10 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 1
Circuit breaker, PowerPacT B, 30A, 2 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%, control wire ON end
Circuit breaker, PowerPacT B, 30A, 2 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%, control wire ON end
Auxiliary contact block,TeSys Control,1 NC early break,for VN12,VN20
Auxiliary contact block,TeSys Control,1 NC early break,for VN12,VN20
Harmony, 22mm Push Button, legend holder 30 x 40 mm, with legend 8 x 27 mm, marked EMERGENCY STOP
Harmony, 22mm Push Button, legend holder 30 x 40 mm, with legend 8 x 27 mm, marked EMERGENCY STOP
Pump or compressor switch 9013GH – adjustable diff. – factory setting
Pump or compressor switch 9013GH - adjustable diff. - factory setting
Pressure switch 9012G – fixed scale – 1 threshold – 3.0 to 150 psig
Pressure switch 9012G - fixed scale - 1 threshold - 3.0 to 150 psig
pre-wired connector – cable 10 m – for passive splitter box – with 8 channels
pre-wired connector - cable 10 m - for passive splitter box - with 8 channels
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 330 A – coil 240 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 240 V AC
Busway I-Line Breakr Plug-in Unit, 60A, H-Frame,Micrologic5.2A,14kA-600V,4W,IP54
Busway I-Line Breakr Plug-in Unit, 60A, H-Frame,Micrologic5.2A,14kA-600V,4W,IP54
EcoStruxure Building Expert Enocean PIR occupancy sensor
EcoStruxure Building Expert Enocean PIR occupancy sensor
9007MS limit switch – top push plunger – 6′ bottom cable
9007MS limit switch - top push plunger - 6' bottom cable
Photoelectric sensors XU, XUB, emitter, 12…24 VDC, cable 2 m
Photoelectric sensors XU, XUB, emitter, 12...24 VDC, cable 2 m
Electronic tag, Radio frequency identification XG, RFID 13.56 MHz, disc Ø 30 x 3, 2000 Bytes
Electronic tag, Radio frequency identification XG, RFID 13.56 MHz, disc Ø 30 x 3, 2000 Bytes
TRANSFORMER CURRENT
TRANSFORMER CURRENT
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 3R
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 3R
Illuminated push-button, Harmony 9001K, metal, metal guard flush, green, 30mm, spring return, LED green, 220-240V, 1 C/O
Illuminated push-button, Harmony 9001K, metal, metal guard flush, green, 30mm, spring return, LED green, 220-240V, 1 C/O
Limit switch lever, 9007, 9007C zinc, fixed length, outside steel roller
Limit switch lever, 9007, 9007C zinc, fixed length, outside steel roller
Auto Switch-Disconnector Masterpact MTZ2- 16HB- UL Name Plate
Auto Switch-Disconnector Masterpact MTZ2- 16HB- UL Name Plate
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 24VDC coil, open
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 24VDC coil, open
Photoelectric sensors XU, XUB, emitter, 12…24 VDC, cable 2 m
Photoelectric sensors XU, XUB, emitter, 12...24 VDC, cable 2 m
Panelboard accessory, NF, lug kit, mechanical, 400A, aluminum/copper
Panelboard accessory, NF, lug kit, mechanical, 400A, aluminum/copper
Circuit breaker, PowerPacT B, 20A, 2 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 20A, 2 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Wall mounted enclosure, Spacial S3X, stainless steel 316L, plain door, 600x400x200mm, IP66
Wall mounted enclosure, Spacial S3X, stainless steel 316L, plain door, 600x400x200mm, IP66
Square D Pumptrol, water pump switch 9013FR, fixed diff., 8.5 5.5 PSI, reverse action
Square D Pumptrol, water pump switch 9013FR, fixed diff., 8.5 5.5 PSI, reverse action
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, NEMA 4/4X
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, NEMA 4/4X
Bracket Hanger, SQUARE-Duct, LJB wireway, Type 12, 2.5in H x 2.5in D
Bracket Hanger, SQUARE-Duct, LJB wireway, Type 12, 2.5in H x 2.5in D
IEC contactor, TeSys Deca Green, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48/130VAC/VDC coil
IEC contactor, TeSys Deca Green, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48/130VAC/VDC coil
Timing Relay, Type JCK, plug In, off delay, adjustable time, 1.2 to 120 seconds, 10A, 240 VAC, 24 VAC/DC
Timing Relay, Type JCK, plug In, off delay, adjustable time, 1.2 to 120 seconds, 10A, 240 VAC, 24 VAC/DC
Marked legend 8 x 27 mm for legend holder 30 x 40 mm – ARRET
Marked legend 8 x 27 mm for legend holder 30 x 40 mm - ARRET
Limit switch, 9007, 600 V 10amp c +options
Limit switch, 9007, 600 V 10amp c +options
EcoStruxure Building Expert-Enocean valve drive for bus or RF
EcoStruxure Building Expert-Enocean valve drive for bus or RF
Limit switch body, Limit switches XC Standard, ZCKM, 1NC+1 NO, slow break, M20
Limit switch body, Limit switches XC Standard, ZCKM, 1NC+1 NO, slow break, M20
Wireless and batteryless transmitter, Harmony XB5R, push button, metal, red, 22mm, spring return
Wireless and batteryless transmitter, Harmony XB5R, push button, metal, red, 22mm, spring return
servo motor BMH, Lexium 32, 3.4Nm, 8000rpm, untapped shaft, without brake, IP54, 16bit encoder, straight, 3 phases
servo motor BMH, Lexium 32, 3.4Nm, 8000rpm, untapped shaft, without brake, IP54, 16bit encoder, straight, 3 phases
LOAD CENTER WHITE
LOAD CENTER WHITE
IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 60VDC coil, open
IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 60VDC coil, open
Enclosure Cover, NQNF, Type 1, Flush, Ventilated, Hinged, 20x44in
Enclosure Cover, NQNF, Type 1, Flush, Ventilated, Hinged, 20x44in
Cables passages, diameter 22-23mm. Mounted in cable entry matrix.Pkg 10
Cables passages, diameter 22-23mm. Mounted in cable entry matrix.Pkg 10
NEMA Control Relay, Type X, master, 10A resistive at 600VAC, 6 normally open contacts, 110/120VAC 50/60Hz coil
NEMA Control Relay, Type X, master, 10A resistive at 600VAC, 6 normally open contacts, 110/120VAC 50/60Hz coil
servo motor BCH, Lexium 28, 180mm, 3000W, 53.56kg.cm², with oil seal, with key, straight connection
servo motor BCH, Lexium 28, 180mm, 3000W, 53.56kg.cm², with oil seal, with key, straight connection
memory card, Modicon M340, SD flash, 8MB with 128MB file storage, for processor
memory card, Modicon M340, SD flash, 8MB with 128MB file storage, for processor
Elbow, I-Line Busway, 4000A, 600VAC, 3 phase, 4 wire, integral ground bus, edge, vert, Cu, 11in x 11in
Elbow, I-Line Busway, 4000A, 600VAC, 3 phase, 4 wire, integral ground bus, edge, vert, Cu, 11in x 11in
Modicon Momentum – Conformal coating – Modbus Plus communication adaptor
Modicon Momentum - Conformal coating - Modbus Plus communication adaptor
NEMA Combination Starter, Type S, 30A fusible disconnect, Size 1, 27A, 5 HP at 240 VAC polyphase, 120 VAC coil, NEMA 1
NEMA Combination Starter, Type S, 30A fusible disconnect, Size 1, 27A, 5 HP at 240 VAC polyphase, 120 VAC coil, NEMA 1
Busway I-Line Breaker Plug-in Unit,250A,J-Frame,Micrologic6.2A,18kA-600V,3W,IP54
Busway I-Line Breaker Plug-in Unit,250A,J-Frame,Micrologic6.2A,18kA-600V,3W,IP54
Photo-electric sensor – XUL – polarised – Sn 4m – 24..240VAC/DC – 1/2″
Photo-electric sensor - XUL - polarised - Sn 4m - 24..240VAC/DC - 1/2"
TeSys GV3 – undervoltage trip – 220 V AC 50Hz
TeSys GV3 - undervoltage trip - 220 V AC 50Hz
Pre wired connectors XZ, elbowed female, M8, 3 pins, cable PUR 2 m
Pre wired connectors XZ, elbowed female, M8, 3 pins, cable PUR 2 m
Busway I-Line Breaker Plug-in Unit,60A,H-Frame,Micrologic3.2S,18kA-600V,3W,IP54
Busway I-Line Breaker Plug-in Unit,60A,H-Frame,Micrologic3.2S,18kA-600V,3W,IP54
Pressure switch, 9012G, adjustable scale, 2 thresholds, 90 to 2900PSIG
Pressure switch, 9012G, adjustable scale, 2 thresholds, 90 to 2900PSIG
Limit switch contact block, Limit switches XC Standard, 1NC+1 NO, slow break, break before make
Limit switch contact block, Limit switches XC Standard, 1NC+1 NO, slow break, break before make
FA/LA MOLDED CASE CIRCUIT BREAKER 600V, 400A, 3P, AUX SWITCH, BELL ALARM
FA/LA MOLDED CASE CIRCUIT BREAKER 600V, 400A, 3P, AUX SWITCH, BELL ALARM
securing hook for modules controller pan
securing hook for modules controller pan
NEMA motor starter, Type S, nonreversing, Size 3, 90A, 50HP at 460VAC, 5kA SCCR, 3 phase, 3 pole, melting alloy, 240VAC coil, open
NEMA motor starter, Type S, nonreversing, Size 3, 90A, 50HP at 460VAC, 5kA SCCR, 3 phase, 3 pole, melting alloy, 240VAC coil, open