The Type T units are designed for the global market and are the best choice when size and cost are of concern. for the global market and are the best choice when size and cost are of concern. This is our most popular and complete offering of industrial control transformers. The following features are included with the Type T transformers sich as they are rated 50/60 Hz. They have customer installable accessories such as covers, fuse blocks and fuse clips. The Type T transformers are designed with various temperature classes. This Industrial Control Transformer is 1 phase and has a rated power of 200 VA. This transformer has a primary voltages of 240 x 480 V and a secondary voltage of 24/120 V with a temperature rise of 80 °C. The dimensions forThis product are 3.2 in (H), 3.75 in (W), 3.59 in (D). This product is compatable with FSC1. This product complys to UL listed & CSA standards.
Transformer, Type T, industrial control, 200VA, 1 phase, 240x480V primary, 25/120V secondary, 80C rise
Transformer, Type T, industrial control, 200VA, 1 phase, 240x480V primary, 25/120V secondary, 80C rise
SKU: 172553339
Category: Power Distribution
Reviews (0)
Be the first to review “Transformer, Type T, industrial control, 200VA, 1 phase, 240x480V primary, 25/120V secondary, 80C rise” Cancel reply
Related products
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Transformer disconnect, 2000VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 2000VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Ring tongue terminal connections kit – for C60 upstream/downstream – set of 2
Ring tongue terminal connections kit - for C60 upstream/downstream - set of 2
Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Reviews
There are no reviews yet.