Powerpact B-Frame Circuit Breaker accessory, LV429427, offers proven performance, flexibility, and reliability. A time delay unit for the MN eliminates the risk of nuisance tripping due to a transient voltage dip lasting less than 200 ms for fixed delay units and up to 3 seconds for adjustable units. For shorter micro-outages, a system of capacitors provides temporary supply to the MN at V > 0.7 Vn to ensure not tripping. PowerPact B-frame ratings and types. Available in 1, 2, 3, and 4-pole unit mount construction & 1, 2, and 3-pole I-Line™ construction. Cost-effective fixed thermal-magnetic trip units from 15-125A up to 600Y/347 Vac. Interrupting ratings include D-18 kA, G-35 kA, and J-65 kA at 480 Vac. Unique I-Line construction mounts into Square D™ panelboards and switchboards. Designed to the same 1.5″ per pole widths as the legacy F-frame, simplifying substitution without blank fillers. Unit mount (aka, lug-lug) construction is 30% smaller in size with 25% more capacity than the legacy unit-mount F-frame design EverLink atented technology. EverLink lug connectors reduce the loosening of cables over time using a spring tension design. EverLink lugs are rated for bare use with fine-stranded conductors up to Class K. EverLink lugs are also available with unique integrated control wire terminals.
MN delay unit, ComPacT NSX/NSXm, fixed time delay 200ms, 220/240VAC 50/60Hz, spare part
MN delay unit, ComPacT NSX/NSXm, fixed time delay 200ms, 220/240VAC 50/60Hz, spare part
SKU: 4278602
Category: Power Distribution
Reviews (0)
Be the first to review “MN delay unit, ComPacT NSX/NSXm, fixed time delay 200ms, 220/240VAC 50/60Hz, spare part” Cancel reply
Related products
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%

Reviews
There are no reviews yet.