8911 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. This three pole definite purpose starter has a full load rating of 50 amperes. This starter has ratings of 3 HP at 115 VAC and 10 HP at 230 VAC single phase. It has a 15 HP at 230 VAC and 30 HP at 460 and 575 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 440/480 VAC 50/60 Hz coil. The starter has straight through wiring. The melting alloy type overload relay uses Type B thermal units to sense over current conditions. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this definite purpose starter. Enclosure is 12.68 inches tall, 7.80 inches wide and 6.30 inches deep. Auxiliary contacts are available for these starters. 8911DPS definite purpose starters are UL component recognized.
Starter, Definite Purpose, nonreversing, 50A, 3 pole, 3 phase, 440/480VAC 50/60Hz coil, melting alloy overload, NEMA 1
Starter, Definite Purpose, nonreversing, 50A, 3 pole, 3 phase, 440/480VAC 50/60Hz coil, melting alloy overload, NEMA 1
SKU: 172544842
Category: Automation & Control
Reviews (0)
Be the first to review “Starter, Definite Purpose, nonreversing, 50A, 3 pole, 3 phase, 440/480VAC 50/60Hz coil, melting alloy overload, NEMA 1” Cancel reply
Related products
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24…240VAC/DC, 1/2″
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24...240VAC/DC, 1/2"
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Vacuum switch 9016G – adjustable scale – 2 thresholds – Set 0 to 23.8 InHg
Vacuum switch 9016G - adjustable scale - 2 thresholds - Set 0 to 23.8 InHg
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Harmony XB5, Antimicrobial Flush mounted push button head, plastic, projecting, black, Ø30, spring return, unmarked, dark grey bezel
Harmony XB5, Antimicrobial Flush mounted push button head, plastic, projecting, black, Ø30, spring return, unmarked, dark grey bezel
Pressure switch 9012G – adjustable scale – 2 thresholds – 1.5 to 75 psig
Pressure switch 9012G - adjustable scale - 2 thresholds - 1.5 to 75 psig

Reviews
There are no reviews yet.