Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 6 non-reversing contactor has a 540 ampere rating. Three phase NEMA Size 6 contactors have 150 HP at 200, 200 HP at 230 VAC and 400 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is an open device without an enclosure. This contactor is 28.06 inches tall, 10.55 inches wide and 9.00 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
NEMA Contactor, Type S, nonreversing, Size 6, 540A, 400HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 6, 540A, 400HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, open
SKU: 172557364
Category: Automation & Control
Reviews (0)
Be the first to review “NEMA Contactor, Type S, nonreversing, Size 6, 540A, 400HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, open” Cancel reply
Related products
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Harmony XB5, Light block with body/fixing collar, plastic, blue, integral LED, 24 V AC/DC, 1 NO + 1 NC
Harmony XB5, Light block with body/fixing collar, plastic, blue, integral LED, 24 V AC/DC, 1 NO + 1 NC

Reviews
There are no reviews yet.