PowerPact electronic Motor Circuit Protectors (MCP) are magnetic-only instantaneous-trip circuit breakers. Designed to offer short circuit protection, they are National Electrical Code (NEC) compliant when installed as part of a combination controller having motor overload protection. PowerPact electronic Motor Circuit Protectors has sensor ratings from 30–1200 A at up to 600 Vac. They have Electronic trip units with adjustable instantaneous trip ranges and comes in 3-pole available in unit mount and I-Line construction. PowerPact electronic Motor Circuit Protectors accept the same accessories and terminals as equivalent PowerPact circuit breakers. PowerPact electronic Motor Circuit Protectors accept the same accessories and terminals as equivalent PowerPact circuit breakers. This PowerPact H, Motor Circuit Protector has a rated current of 30A and is a 3P breaker. This breaker has a breaking capacity of 25 kA@600VAC and has an electronic trip technology. This breaker complies to UL, CE, IEC & CSA standards. Thermal current for this breaker are 1.5-25 A with a magnetic tripping current of 9-325A. This product comes with an 18 months warranty.
Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, 80% rated
Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, 80% rated
SKU: 2944715
Category: Circuit Breakers
Reviews (0)
Be the first to review “Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, 80% rated” Cancel reply
Related products
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker accessory, PowerPacT P/R, MicroLogic, rating plug, UL/ANSI, type B
Circuit breaker accessory, PowerPacT P/R, MicroLogic, rating plug, UL/ANSI, type B
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Reviews
There are no reviews yet.