E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This device is a 2 pole bolt-on breaker that is rated at 60 A at a system voltage of 480Y/277 VAC and the breaker is UL Listed as well as CSA rated. This E-Frame breaker has thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. This specific breaker is HACR rated. The breaker has aluminium lugs which have a terminal lug rating of AWG 12…AWG 2/0 (aluminium) and AWG 14…AWG 2/0 (copper). This E-frame breaker breaking capacity has been tested a numerous voltages but at two voltages the capacity is 18 kA at 480Y/277 VAC and 25 kA at 120/240 VAC. This device has a hold current of 630 A which is the maxiumum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. The circuit breaker has a height of 5.66 in, width of 1.96 in and a depth of 4.05 in. This breaker was calibrated for 40 degrees C. HACR rated.
Mini circuit breaker, E-Frame, 60A, 2 pole, 480Y/277 VAC, 25 kA max, bolt on
Mini circuit breaker, E-Frame, 60A, 2 pole, 480Y/277 VAC, 25 kA max, bolt on
SKU: 1309830
Category: Power Distribution
Reviews (0)
Be the first to review “Mini circuit breaker, E-Frame, 60A, 2 pole, 480Y/277 VAC, 25 kA max, bolt on” Cancel reply
Related products
Circuit breaker, PowerPacT H, 80A, 2 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, BC
Circuit breaker, PowerPacT H, 80A, 2 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, BC
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
Reviews
There are no reviews yet.