UT horizontal ganged meter sockets are for single phase systems up to 600 VAC. These main lug units can be from 2 through 6 meter positions. Units can be with or with a horn or lever bypass and be fed from the end or the center. This horizontal ganged meter socket has four meter positions without bypass. Each socket position has a 4 jaw socket without jaw release. The main is rated at 205 A. The branches have a 100 A rating. This unit can be feed from an overhead or underground service. This unit has a NEMA 3R surface mounting enclosure that is 14.12 inches tall, 40.62 inches wide and 4.50 inches deep. The main lugs, phase and neutral, will accept 6 AWG to 350 kcmil copper or aluminum wire. The branch lugs will accept 8 AWG to 2/0 AWG copper or aluminum wire. This horizontal ganged meter socket device is UL Listed.
Horizontal meter sockets, 4 ringless sockets, no bypass, 4 jaws, OH, UG, 100 A
Horizontal meter sockets, 4 ringless sockets, no bypass, 4 jaws, OH, UG, 100 A
SKU: 8966871
Category: Power Distribution
Reviews (0)
Be the first to review “Horizontal meter sockets, 4 ringless sockets, no bypass, 4 jaws, OH, UG, 100 A” Cancel reply
Related products
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Multi 9 – C60H – MCB – 4P – 63 A – D Curve – 415 V – 15 kA
Multi 9 - C60H - MCB - 4P - 63 A - D Curve - 415 V - 15 kA
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%

Reviews
There are no reviews yet.