UT horizontal ganged meter sockets are for single phase systems up to 600 VAC. These main lug units can be from 2 through 6 meter positions. Units can be with or with a horn or lever bypass and be fed from the end or the center. This horizontal ganged meter socket has four meter positions without bypass. Each socket position has a 4 jaw socket without jaw release. The main is rated at 205 A. The branches have a 100 A rating. This unit can be feed from an overhead or underground service. This unit has a NEMA 3R surface mounting enclosure that is 14.12 inches tall, 40.62 inches wide and 4.50 inches deep. The main lugs, phase and neutral, will accept 6 AWG to 350 kcmil copper or aluminum wire. The branch lugs will accept 8 AWG to 2/0 AWG copper or aluminum wire. This horizontal ganged meter socket device is UL Listed.
Horizontal meter sockets, 4 ringless sockets, no bypass, 4 jaws, OH, UG, 100 A
Horizontal meter sockets, 4 ringless sockets, no bypass, 4 jaws, OH, UG, 100 A
SKU: 8966871
Category: Power Distribution
Reviews (0)
Be the first to review “Horizontal meter sockets, 4 ringless sockets, no bypass, 4 jaws, OH, UG, 100 A” Cancel reply
Related products
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Reviews
There are no reviews yet.