Homeline All In One combination service entrance devices are available with ring or ringless type meter socket designs. Devices have factory installed service disconnect(s) in most cases. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These Homeline combination service entrance devices meet the Federal Specification W-P-115c as Type 1, Class 2 specifications. This Homeline All In One combination service entrance device has a ringed meter socket with no bypass. This unit can be feed from an overhead or underground service. The service disconnect is a QOM2150VH with a maximum rating of 150 A. Device has a 22 kA short circuit current rating. Load center has 8 spaces which will accept up to 8 tandem Homeline circuit breakers. This unit has a NEMA 3R surface mount enclosure that is 30.26 inches tall, 21.50 inches wide and 6.30 inches deep. The line side lugs will accept 4 AWG to 250 kcmil copper or aluminum wire. The service ground lug will accept 8 AWG to 2/0 AWG copper or aluminum wire. This Homeline All In One combination service entrance meter main unit is UL Listed. Device meets EUSERC standards. Solar ready kit SR69064A fits this device.
Homeline All In One combination service entrance device, ringed socket, no bypass, OH, UG, 150 A, 8 spaces, solar ready
Homeline All In One combination service entrance device, ringed socket, no bypass, OH, UG, 150 A, 8 spaces, solar ready
SKU: 1439265
Category: Power Distribution
Reviews (0)
Be the first to review “Homeline All In One combination service entrance device, ringed socket, no bypass, OH, UG, 150 A, 8 spaces, solar ready” Cancel reply
Related products
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Circuit breaker, PowerPact H, thermal magnetic, 80A, 3 pole, 600V, 25kA, shunt trip, control wire both ends
Circuit breaker, PowerPact H, thermal magnetic, 80A, 3 pole, 600V, 25kA, shunt trip, control wire both ends
Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%

Reviews
There are no reviews yet.