The PowerPact L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. L-frame circuit breakers are available with Micrologic electronic trip units only. The new generation PowerPact with Micrologic circuit breakers set the standard with direct access to energy management. Integrated metering enhances their protective functions. For the first time, Schneider Electricâ„¢ users can monitor energy from 15 to 3000A, offering new performance in a remarkably compact device. Electronic trip units provide highly accurate protection with wide setting ranges and can integrate measurement, metering and communication functions. They can be combined with the front display module (FDM121) to provide functions similar to a power meter. This 3-pole circuit breaker has a 400A rated current. This breaker has a breaking capacity of 10 kA@250VDC operation voltage. This breaker has a thermal-magnetic trip technology. The dimensions are 11 in (H), 6 in (W), 5.84 in (D).
FA/LA MOLDED CASE CIRCUIT BREAKER, 600V, 400A, 3P, SHORT HANDLE
FA/LA MOLDED CASE CIRCUIT BREAKER, 600V, 400A, 3P, SHORT HANDLE
SKU: 894340
Category: Power Distribution
Reviews (0)
Be the first to review “FA/LA MOLDED CASE CIRCUIT BREAKER, 600V, 400A, 3P, SHORT HANDLE” Cancel reply
Related products
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPact H, thermal magnetic, 80A, 3 pole, 600V, 25kA, shunt trip, control wire both ends
Circuit breaker, PowerPact H, thermal magnetic, 80A, 3 pole, 600V, 25kA, shunt trip, control wire both ends
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term

Reviews
There are no reviews yet.