E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This device is a 3 pole bolt-on breaker that is rated at 35 A at a system voltage of 480Y/277 VAC and the breaker is UL Listed as well as CSA rated. This E-Frame breaker has thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. This specific breaker is HID rated and HACR rated. The breaker has aluminium lugs which have a terminal lug rating of AWG 12…AWG 2/0 (aluminium) and AWG 14…AWG 2/0 (copper). This E-frame breaker breaking capacity has been tested a numerous voltages but at two voltages the capacity is 18 kA at 480Y/277 VAC and 25 kA at 120/240 VAC. This device has a hold current of 630 A which is the maxiumum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. The circuit breaker has a height of 5.66 in, width of 2.94 in and a depth of 4.05 in. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
Mini circuit breaker, E-Frame, 35A, 3 pole, 480Y/277 VAC, 25 kA max, bolt on
Mini circuit breaker, E-Frame, 35A, 3 pole, 480Y/277 VAC, 25 kA max, bolt on
SKU: 1258597
Category: Power Distribution
Reviews (0)
Be the first to review “Mini circuit breaker, E-Frame, 35A, 3 pole, 480Y/277 VAC, 25 kA max, bolt on” Cancel reply
Related products
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 45A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, CBA
Circuit breaker, PowerPacT H, 45A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, CBA
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, I-Line, Micrologic 5.2E, 80%, ABC
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Reviews
There are no reviews yet.