The PowerPacT™ H-, J-, and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. H- and J-frame circuit breakers are available with either thermal-magnetic or Micrologic™ electronic trip units. L-frame circuit breakers are available with Micrologic electronic trip units only. Shunt Trip (MX). Trips the circuit breaker when the control voltage rises above 70% of its rated voltage. Impulse type ≥ 20 ms or maintained control signals. AC shunt trips are suitable for ground-fault protection when combined with a Class I ground-fault sensing element. Continuous duty rated coil.
Circuit breaker accessory, PowerPacT H/J/L, undervoltage trip, 48VDC
Circuit breaker accessory, PowerPacT H/J/L, undervoltage trip, 48VDC
SKU: 4658591
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker accessory, PowerPacT H/J/L, undervoltage trip, 48VDC” Cancel reply
Related products
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT J, 200A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%, aux
Circuit breaker, PowerPacT J, 200A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%, aux
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT B, 20A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 20A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT H, thermal magnetic, unit mount, 60A, 3 pole, 18 kA, 600 VAC, shunt trip, copper lugs, 80%
Circuit breaker, PowerPacT H, thermal magnetic, unit mount, 60A, 3 pole, 18 kA, 600 VAC, shunt trip, copper lugs, 80%
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Reviews
There are no reviews yet.