The PowerPact H-, J-, and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. H- and J-frame circuit breakers are available with either thermal-magnetic or Micrologic electronic trip units. The new generation PowerPact with Micrologic circuit breakers set the standard with direct access to energy management. Integrated metering enhances their protective functions. For the first time, Schneider Electric™ users can monitor energy from 15 to 3000 A, offering new performance in a remarkably compact device. This PowerPact H, circuit breaker has a rated current of 60A and is a 3P breaker. This breaker has a breaking capacity of 50 kA@600VAC and has an electronic trip technology. This breaker complies to UL, CE, IEC & CSA standards. This breaker has a Micrologic Energy with a 6.2E trip unit and a LSIG function. Dimensions for this breaker are 9.73 in (H),4.48 in (W),4.36 in (D) and has an ambient temperature of 40 °C. This product comes with an 18 months warranty.
Circuit breaker, PowerPact H, I Line, Micrologic 6.2E, 60A, 3 pole, 600V, 50kA, phase ABC
Circuit breaker, PowerPact H, I Line, Micrologic 6.2E, 60A, 3 pole, 600V, 50kA, phase ABC
SKU: 16942542
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPact H, I Line, Micrologic 6.2E, 60A, 3 pole, 600V, 50kA, phase ABC” Cancel reply
Related products
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Multi 9 – C60H – MCB – 4P – 63 A – D Curve – 415 V – 15 kA
Multi 9 - C60H - MCB - 4P - 63 A - D Curve - 415 V - 15 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches

Reviews
There are no reviews yet.