It is a single standard auxiliary contact that provides two remote information of the circuit breaker status. It is used on Compact NSXm and PowerPact B devices. The OF contact (open/closed) indicates the position of the circuit breaker main contacts. The SD contact (trip indication) indicates if the circuit breaker has tripped. There is one auxiliary contact model for OF and SD information, depending on where it is fitted in the device. This auxiliary is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 5A and the minimum load is 2mA at 17 VDC. Utilization categories are AC12/AC13/DC12/DC13/DC14. Compact NSXm embeds 2 auxiliary contacts and their presence is visible on the front face through green flags. It complies with IEC 60947-5-1 standard.
standard auxiliary contact, ComPact NSXm, circuit breaker status OF/SD, 1 changeover contact type
standard auxiliary contact, ComPact NSXm, circuit breaker status OF/SD, 1 changeover contact type
SKU: 4278044
Category: Circuit Breakers
Reviews (0)
Be the first to review “standard auxiliary contact, ComPact NSXm, circuit breaker status OF/SD, 1 changeover contact type” Cancel reply
Related products
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 10A, Z curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 10A, Z curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Mini circuit breaker, QO, 20A, 2 pole, 120/240VAC, 10kA, bolt on, AC shunt, ring
Mini circuit breaker, QO, 20A, 2 pole, 120/240VAC, 10kA, bolt on, AC shunt, ring
Circuit breaker accessory, PowerPacT J, terminal nut, for busbar, tap M8, CE standard, qty 2
Circuit breaker accessory, PowerPacT J, terminal nut, for busbar, tap M8, CE standard, qty 2
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker, PowerPacT J, 175A, 2 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, AC
Circuit breaker, PowerPacT J, 175A, 2 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, AC
Circuit breaker, PowerPacT H, 40A, 3 pole, 600VAC, 18kA, busbar, thermal magnetic, 80%
Circuit breaker, PowerPacT H, 40A, 3 pole, 600VAC, 18kA, busbar, thermal magnetic, 80%
Circuit breaker, PowerPacT Q, 150A, 3 pole, 240VAC, 10kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT Q, 150A, 3 pole, 240VAC, 10kA, lugs, thermal magnetic, 80%
Reviews
There are no reviews yet.