These industrial heavy duty limit switches are applied in almost any environments. The lever head switches have the largest diameter shaft in the industry. They also have a Viton Quadring shaft seal to ensure positive head and shaft sealing that is dust and watertight. This maintained contact lever head limit switch has a body and receptacle which is good for hazardous locations. Limit switch has one normally open and one normally closed contact. The snap action contacts will trip when the lever arm is turned in the clockwise direction. The switch will reset when the lever arm is moved in the counterclockwise direction. Contacts have an A600 and Q600 inductive ratings and 10A resistive rating. The proper lever arm for the application must be purchased separately. This limit switch is 6.10 inches tall, 2.72 inches wide and 2.79 inches deep. This limit switch is UL Listed for hazardous locations, Division I, Class I, Groups B, C, D and Class II, Groups E, F, G. Switch has a 0.50 inch conduit entry with 14 NPT. Limit switch is UL listed and CSA certified. The 9007C heavy duty metal limit switches, compact and standard, with 39mm plug-in bodies or 69mm fixed body for hazardous locations. The 9007 series limit switches are designed to withstand harsh industrial environments and are available in a wide range of options.
NEMA limit switch, 9007C, heavy duty, standard, maintained contact lever, 10A, 600V, 1NO/1NC, NEMA 7/9
NEMA limit switch, 9007C, heavy duty, standard, maintained contact lever, 10A, 600V, 1NO/1NC, NEMA 7/9
SKU: 3026544
Category: Sensors & Switches
Reviews (0)
Be the first to review “NEMA limit switch, 9007C, heavy duty, standard, maintained contact lever, 10A, 600V, 1NO/1NC, NEMA 7/9” Cancel reply
Related products
9007MS limit switch – cross roller plunger – booted – 12′ bottom cable
9007MS limit switch - cross roller plunger - booted - 12' bottom cable
Inductive proximity sensors XS, inductive sensor XS5 M30, L62mm, brass, Sn10mm, 12…48 VDC, cable 2 m
Inductive proximity sensors XS, inductive sensor XS5 M30, L62mm, brass, Sn10mm, 12...48 VDC, cable 2 m
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m
Photo-electric sensor – XUB – multi – Sn 0..20m – 12..24VDC – cable 5m
Photo-electric sensor - XUB - multi - Sn 0..20m - 12..24VDC - cable 5m
Photo-electric sensor – XUB – receiver – 90° – Sn 15m – 12..24VDC – M12
Photo-electric sensor - XUB - receiver - 90° - Sn 15m - 12..24VDC - M12
inductive sensor XS1 M12, L33mm, brass, Sn2mm, 12..24 VDC, cable 2 m
inductive sensor XS1 M12, L33mm, brass, Sn2mm, 12..24 VDC, cable 2 m
Pump or compressor switch 9013GH – adjustable diff. – 125-175 psi
Pump or compressor switch 9013GH - adjustable diff. - 125-175 psi
Air compressor switch 9013FH – fixed differential – Off at 150 psi – low hp
Air compressor switch 9013FH - fixed differential - Off at 150 psi - low hp
Reviews
There are no reviews yet.