The PowerPact™ J-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. J-frame circuit breakers are available with either thermal-magnetic or Micrologic™ electronic trip units. The amperage ratings of the thermal trip elements are calibrated at 104°F (40°C) free air ambient temperature. Per the National Electric Code® (NEC®) and the Canadian Electrical Code, standard circuit breakers may only be applied continuously at up to 80% of their rating. This PowerPact J, circuit breaker and is 3-pole and has a breaking capacity of 14kA@600VAC and has a rated current of 225A. This ia a unit mount breaker and complies to UL listed, IEC, CCC, CE & CSA standards. With a magnetic hold current of 1125A and a magnetic tripping current of 2250-2250A Dimensions for this product are 7.52 in (H),4.12 in (W), 5 in (D) with an ambient temperature rating of 40 °C. This product comes with an 18 month warranty.
PowerPact J-Frame breaker, thermal-magnetic, 225 A, 3P, 14 kA at 600 VAC
PowerPact J-Frame breaker, thermal-magnetic, 225 A, 3P, 14 kA at 600 VAC
SKU: 3428603
Category: Power Distribution
Reviews (0)
Be the first to review “PowerPact J-Frame breaker, thermal-magnetic, 225 A, 3P, 14 kA at 600 VAC” Cancel reply
Related products
Circuit breaker accessory, PowerPacT J, rear connection kit, 3 pole, mixed, 4x short, 2x covers
Circuit breaker accessory, PowerPacT J, rear connection kit, 3 pole, mixed, 4x short, 2x covers
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term

Reviews
There are no reviews yet.