This XUSL2E Type 2 Safety Light Curtain is designed for hand detection of operator in the vicinity of hazardous machinery. Its transmitter-receiver system creates 53 light beams with a protected height of 1060mm. Its PFHD reliability data is 5.83 x 10⁻⁸. It has an aluminum case and its integral LEDs offer a local Signaling for clearly display of device’s status. It can be used as standalone sensor (i.e without safety control unit) or in association with an appropriate safety control unit. It has 2 NO Solid State PNP safety outputs (OSSDs) and meets the requirements of category 2, performance level PL c, SIL 1 as described in EN/ISO 13849-1, EN/IEC 61508 and Type 2 in compliance with EN/IEC 61496-1, EN/IEC 61496-2. Its operating temperature range is -30°C to +55°C and the sensing distance is 0m to 4m or 0m to 12m selectable by wiring.
Safety light curtain type 2, Telemecanique Safety light curtains XUSL, XUSL Hand protection, Std sensing range, Hp = 1060 mm, R=30 mm
Safety light curtain type 2, Telemecanique Safety light curtains XUSL, XUSL Hand protection, Std sensing range, Hp = 1060 mm, R=30 mm
SKU: 9178584
Category: Sensors & Switches
Reviews (0)
Be the first to review “Safety light curtain type 2, Telemecanique Safety light curtains XUSL, XUSL Hand protection, Std sensing range, Hp = 1060 mm, R=30 mm” Cancel reply
Related products
inductive sensor XS1 M12, L33mm, brass, Sn2mm, 12..24 VDC, cable 2 m
inductive sensor XS1 M12, L33mm, brass, Sn2mm, 12..24 VDC, cable 2 m
Photo-electric sensor – XUB – multi – Sn 0..20m – 12..24VDC – cable 5m
Photo-electric sensor - XUB - multi - Sn 0..20m - 12..24VDC - cable 5m
Plastic fibre optic for sensor – diffuse – lateral – multistrand – 2m – Sn80mm
Plastic fibre optic for sensor - diffuse - lateral - multistrand - 2m - Sn80mm
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMP, 1 NC + 1 NO, staggered, 10 m
9007MS limit switch – cross roller plunger – booted – 12′ bottom cable
9007MS limit switch - cross roller plunger - booted - 12' bottom cable
Inductive proximity sensors XS, inductive sensor XS5 M30, L62mm, brass, Sn10mm, 12…48 VDC, cable 2 m
Inductive proximity sensors XS, inductive sensor XS5 M30, L62mm, brass, Sn10mm, 12...48 VDC, cable 2 m
Operating mechanism, disconnect switch, 30 A, 600 VAC, NEMA Size 0 and 1
Operating mechanism, disconnect switch, 30 A, 600 VAC, NEMA Size 0 and 1
Reviews
There are no reviews yet.