A Buck & Boost Transformer is an insulating transformer with either a 120 V x 240 V primary with a 12/24 V or 16/32 V secondary, or a 240 V x 480 V primary with a 24/48 V secondary. A Buck & Boost Transformer is also useful in applications where the primary and secondary are interconnected for use as an autotransformer. The equipment enclosure is designed and constructed for indoor or outdoor use and is NEMA 3R rated. Square D Buck and Boost Transformers are UL and cUL listed. This Buck and Boost Transformer is a 1 phase, and has a NEMA 3R enclosure rating. This transformer has a primary voltage of 240 x 480 V and a secondary voltage of 24/48 V. This product have a temperature rise of 115 °C. Dimensions for this product are 210 mm (H), 220 mm (W), 167 mm(D), and a weight of 30.1 lb(US).
Transformer, buck boost, encapsulated, 0.15kVA, 1 phase, 120x240V primary, 12/24V secondary, NEMA 3R, 55C rise
Transformer, buck boost, encapsulated, 0.15kVA, 1 phase, 120x240V primary, 12/24V secondary, NEMA 3R, 55C rise
SKU: 14311451
Category: Power Distribution
Reviews (0)
Be the first to review “Transformer, buck boost, encapsulated, 0.15kVA, 1 phase, 120x240V primary, 12/24V secondary, NEMA 3R, 55C rise” Cancel reply
Related products
Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 125A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT H, 125A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Straight length, I-Line Busway, 1000A, 600VAC, 3 phase, 3 wire, integral ground bus, Al, plug-in, 10ft
Straight length, I-Line Busway, 1000A, 600VAC, 3 phase, 3 wire, integral ground bus, Al, plug-in, 10ft
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Reviews
There are no reviews yet.