Well-Guard pumping plant panels are designed for pumping applications. These panels provide extra space for field installation of auxiliary equipment. These panels use Type S non-reversing magnetic starters. Panel has a 100A fusible disconnect switch for Class H or K fuses. This panel has a 3 pole NEMA Size 3 non-reversing starter that has a 90 ampere rating. This NEMA Size 3 starter has maximum of 40 HP and 50 HP ratings three phase. This non-reversing NEMA motor starter has an IEC ambient compensated bimetallic overload relay to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. The starters in these panels are available with a wide variety of replaceable coil voltages. The starter in this device has a 440/480 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 3R rainproof enclosure is used to protect this starter. Enclosure is 49.00 inches tall, 19.15 inches wide and 10.37 inches deep. A wide variety of accessories are available for Type S starters. This pump panel is supplied with a START momentary push button and a HAND/OFF/AUTO selector switch. These NEMA pump panels with Type S starters are UL listed and marked Suitable for use as Service Equipment. They are also CSA certified.
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, IEC bimetallic overload, 480 VAC 60 Hz coil, NEMA 3R
Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, IEC bimetallic overload, 480 VAC 60 Hz coil, NEMA 3R
SKU: 14197928
Category: Automation & Control
Reviews (0)
Be the first to review “Pump Panel, NEMA Type S, Well Guard, Size 3, 90A, 5 kA SCCR, 50 HP, 100A Class H and K fuse clip, IEC bimetallic overload, 480 VAC 60 Hz coil, NEMA 3R” Cancel reply
Related products
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Modular box PC, Harmony iPC, HMIBM Performance DC Base unit 8 GB 4 slots
Modular box PC, Harmony iPC, HMIBM Performance DC Base unit 8 GB 4 slots
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Reviews
There are no reviews yet.