Thermal units are intended to protect motors, controllers, and branch-circuit conductors against excessive heating due to prolonged motor over-currents up to and including locked rotor currents. Protection of the motor and the other branch circuit components from higher currents, due to short circuits or grounds, is a function of the branch circuit fuses or circuit breakers. Class 20 thermal units respond to overload current conditions according to trip curves. These thermal units will trip in 20 seconds or less on overload conditions. These thermal units have a one piece construction. The motor current passes through a small heater winding within these thermal units. Under overload conditions, the heat causes a special solder to melt allowing a ratchet wheel to spin free thus opening the control circuit contacts and opening the motor contacts.
Thermal Unit, Type S, Type A, melting alloy, Class 20
Thermal Unit, Type S, Type A, melting alloy, Class 20
SKU: 894465
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “Thermal Unit, Type S, Type A, melting alloy, Class 20” Cancel reply
Related products
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 330 A – coil 240 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 240 V AC
Magnetic latching contactor,TeSys F,3P(3NO),AC-3 <=440V 185A,220-230V DC coil
Magnetic latching contactor,TeSys F,3P(3NO),AC-3 <=440V 185A,220-230V DC coil
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 2 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 2 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 660 to 690VAC coil
Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 660 to 690VAC coil
IEC contactor, TeSys Deca Green, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60 VAC/VDC coil, open
IEC contactor, TeSys Deca Green, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60 VAC/VDC coil, open
NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 25 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 12
NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 25 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 480 VAC coil, NEMA 12
IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 4 NO, low consumption 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 4 NO, low consumption 24VDC coil, open style
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 380 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 380 V AC
Reviews
There are no reviews yet.