The coil can be easily replaced in a Type S contactor or starter. By changing out the coil, the contactor or starter can be used in different control circuit voltage applications. This will also save the cost of a whole new contactor or starter if the coil were to fail. This coil is used in an 8502SG Series A contactor, an 8536SG Series A starter or an 8903SX Series A lighting contactor. The coil is rated for 440/480 VAC 50/60 Hz. The inrush power of this coil is 2970 VA. It has an average sealed consumption of 212 VA. This coil has a height of 140.5 mm, a width of 101.2 mm. Coil is fully encapsulated to protect it. Coil has screw clamp connections.
NEMA Motor Starter, Type S, replacement coil, Series A, 440/480VAC 50/60Hz, NEMA size 5 starter and 8903SX lighting
NEMA Motor Starter, Type S, replacement coil, Series A, 440/480VAC 50/60Hz, NEMA size 5 starter and 8903SX lighting
SKU: 15364745
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, replacement coil, Series A, 440/480VAC 50/60Hz, NEMA size 5 starter and 8903SX lighting” Cancel reply
Related products
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 48VAC coil
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 48VAC coil
Thermal Unit, Type S, Type B, melting alloy, Class 20
Thermal Unit, Type S, Type B, melting alloy, Class 20
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 380 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 380 V AC
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 120 VAC coil, open
IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 4 NO, 48VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 4 NO, 48VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VDC coil, open style
Magnetic latching contactor,TeSys F,3P(3NO),AC-3 <=440V 185A,220-230V DC coil
Magnetic latching contactor,TeSys F,3P(3NO),AC-3 <=440V 185A,220-230V DC coil
Reviews
There are no reviews yet.