Type S magnetic contactors and starters are for motor control applications and 8903S lighting contactors are for lighting control applications. This transient suppression module is designed to be used to suppress the voltage spike generated when opening coil circuit. This voltage spike can cause issue with nearby integrated and solid state control circuits. The module consists of an RC circuit. It is designed to suppress the coil voltage transients to approximately 200% of peak coil supply voltage. It is designed for coil voltages of 120 VAC. This module can be used with NEMA size 00, 0, 1, and 2 devices. This module is UL listed and UL component recognized.
NEMA Motor Starter and contactor, Type S, transient suppression module, NEMA size 00 through 2, 120VAC 60Hz
NEMA Motor Starter and contactor, Type S, transient suppression module, NEMA size 00 through 2, 120VAC 60Hz
SKU: 1276324
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “NEMA Motor Starter and contactor, Type S, transient suppression module, NEMA size 00 through 2, 120VAC 60Hz” Cancel reply
Related products
NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 25HP at 600VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 1
NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 25HP at 600VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 1
NEMA Contactor and NEMA Motor Starter, Type S, replacement contact kit, 8502SG, 8536SG, 8903SX, NEMA size 5, 300A, 3 pole
NEMA Contactor and NEMA Motor Starter, Type S, replacement contact kit, 8502SG, 8536SG, 8903SX, NEMA size 5, 300A, 3 pole
Contactor, IEC, TeSys K, 9A, 3 P, 5 HP at 480VAC, nonreversing, 1 NO auxilliary contact, 120VAC 50/60 Hz coil
Contactor, IEC, TeSys K, 9A, 3 P, 5 HP at 480VAC, nonreversing, 1 NO auxilliary contact, 120VAC 50/60 Hz coil
TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 48 V AC coil
TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 48 V AC coil
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style
NEMA Contactor, TeSys N, reversing, Size 2, 45A, 25HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open
NEMA Contactor, TeSys N, reversing, Size 2, 45A, 25HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open
Reviews
There are no reviews yet.