TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. The 3 pole NEMA size 2 motor starter has a 45 amperage continuous current rating. It also has ratings of 10 HP at 200 VAC, of 15 HP at 230 VAC, of 25 HP at 460 and 575 VAC poly phase. This motor starter has a Motor Logic solid state overload relay with a Class 10/20 rating. The overload is adjustable from 15 to 45 amperes. The starter has a 120 VAC replaceable coil with common control. Starter has 1 normally open and 1 normally closed auxiliary contact. This starter is not in an enclosure. Motor starter is UL listed and CSA Certified.
Motor Starter, TeSys NEMA, nonreversing, Size 2, 45A, 3 pole, HP rated, Motor Logic SSOLR, 120 VAC 60 Hz coil, open
Motor Starter, TeSys NEMA, nonreversing, Size 2, 45A, 3 pole, HP rated, Motor Logic SSOLR, 120 VAC 60 Hz coil, open
SKU: 485608
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “Motor Starter, TeSys NEMA, nonreversing, Size 2, 45A, 3 pole, HP rated, Motor Logic SSOLR, 120 VAC 60 Hz coil, open” Cancel reply
Related products
IEC contactor, TeSys Deca, nonreversing, 150A, 100HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 150A, 100HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VAC 50/60Hz coil, open
Contactor, IEC, TeSys K, 9A, 3 P, 5 HP at 480VAC, nonreversing, 1 NO auxilliary contact, 120VAC 50/60 Hz coil
Contactor, IEC, TeSys K, 9A, 3 P, 5 HP at 480VAC, nonreversing, 1 NO auxilliary contact, 120VAC 50/60 Hz coil
Contactor, TeSys K, 4P, 4 NO, AC-1, lt or eq to 440V, 20A, 12VDC coil
Contactor, TeSys K, 4P, 4 NO, AC-1, lt or eq to 440V, 20A, 12VDC coil
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style
NEMA Starter, Type S, reversing, vertical, Size 5, 270A, 200 HP at 575 VAC, 10 kA SCCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, open
NEMA Starter, Type S, reversing, vertical, Size 5, 270A, 200 HP at 575 VAC, 10 kA SCCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, open
Thermal Unit, Type S, Type B, melting alloy, Class 20
Thermal Unit, Type S, Type B, melting alloy, Class 20
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 225 A – coil 240 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 225 A - coil 240 V AC
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 110VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 110VDC coil, open style
Reviews
There are no reviews yet.