TeSys GV manual self protected combination starters meet the requirements of UL 508 Type F, see UL File E164871. Manual motor starter consists of a GV2P16 motor starter protector and a LC1D25G7 IEC contactor assembled together into one device. The GV2P16 high performance manual starter with a rotary handle offers a high withstand rating and visible trip indication. The GV2P16 provides trip on overload, short circuit, undervoltage, or shunt trip. It has a 9.0 to 14.0 A thermal setting. The LC1D09B7 IEC contactor is rated 9 amperes and has a 24 VAC 50/60 Hz coil.
Motor Starter Kit, TeSys, LC1D25G7 contactor, GV2P16 motor starter protector, 120 VAC 50/60 Hz coil, 9 to 14A trip
Motor Starter Kit, TeSys, LC1D25G7 contactor, GV2P16 motor starter protector, 120 VAC 50/60 Hz coil, 9 to 14A trip
SKU: 9181714
Category: Automation & Control
Reviews (0)
Be the first to review “Motor Starter Kit, TeSys, LC1D25G7 contactor, GV2P16 motor starter protector, 120 VAC 50/60 Hz coil, 9 to 14A trip” Cancel reply
Related products
Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
discrete output module Modicon Quantum – 32 O – positive logic (source)
discrete output module Modicon Quantum - 32 O - positive logic (source)
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
interface plug-in relay, Harmony electromechanical relays, 12A, 1CO, 48V AC
interface plug-in relay, Harmony electromechanical relays, 12A, 1CO, 48V AC
Vacuum switch 9016G – adjustable scale – 2 thresholds – Set 0 to 23.8 InHg
Vacuum switch 9016G - adjustable scale - 2 thresholds - Set 0 to 23.8 InHg
TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m

Reviews
There are no reviews yet.