GV7RE40 is a TeSys GV7R motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 15-18.5kW@400V with breaking capacity Icu 36kA. Start-stop control by rocker lever guaranteed for 30 000 cycles AC-3 415V. GV7RE40 is a TeSys GV7R motor circuit breaker from Schneider Electric designed for motor applications 15-18.5kW@400V. It fulfills thermal-magnetic protection with a thermal setting range 25-40A, magnetic tripping at 12-14xIn and breaking capacity Icu 36kA@400V. Start-stop control by rocker lever guaranteed for 30 000 cycles AC-3 415V. Available worldwide, it is multi-standards certified (IEC, UL, CSA, Marine). Complete motor protection in a single device , short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution. For industrial or building LV distribution networks thanks to 36kA breaking capacity. Power connections with screw clamp terminals. Manual control with rocker lever for Start / Stop, padlockable with accessory (GV7V). Possible integration of auxiliary contacts (GV7AB, GV7AD, GV7AE) for status and tripping signaling. Possible integration of undervoltage or shunt tripping units (GV7AU, GV7AS).
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 25…40 A
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 25…40 A
SKU: 485823
Category: Starters & Contactors
Reviews (0)
Be the first to review “TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 25…40 A” Cancel reply
Related products
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
Well-Guard Pump Panel Size 4, Motor Logic SSOLR, 240 VAC, NEMA 3R +Options
Well-Guard Pump Panel Size 4, Motor Logic SSOLR, 240 VAC, NEMA 3R +Options
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1

Reviews
There are no reviews yet.