2510K manual motor switches are designed for manual On Off control for small motors. This two pole switch is rated for 2 HP at 115VAC, 2 HP at 230VAC, 3 HP at 460VAC, and 3 HP at 600VAC single phase. It is also rated for 1 HP at 90 VDC, 2 HP at 115 VDC and 1.5 HP at 230 VDC motors. Overload protection for the motor must be supplied separately. 2510K switches can be ordered in a variety of enclosure types. This device is in a surface mount NEMA 4 watertight enclosure. A 3/4 inch conduit opening is on the top and bottom of the enclosure. Enclosure as a provision to allow padlocking of this device. 2510K manual switches are UL listed and CSA certified. This switch has no pilot light indicator. A NEMA 4 watertight and dusttight die cast zinc alloy enclosure is used to protect this manual motor switch. This enclosure has one conduit entry on the bottom and one on the top. The 0.75 inch conduit entries are tapped with number 14 pipe threads. This device is 4.38 inches tall, 3.00 inches wide and 4.25 inches deep. A toggle handle is used to turn the manual starter on and off. The toggle handle can be padlocked in the off position. This device is UL Listed and CSA certified.
Switch, manual, 30A, 2 pole, 3 HP at 575 VAC, single phase, toggle operated, red 115 VAC indicator, NEMA 4, two conduit
Switch, manual, 30A, 2 pole, 3 HP at 575 VAC, single phase, toggle operated, red 115 VAC indicator, NEMA 4, two conduit
	
			
		SKU: 172554359
	
	Category: Automation & Control
	
	
							
											
				Reviews (0)
				
					
						
							
	
			
					
		
	
	
						
					
				
			
					
		Be the first to review “Switch, manual, 30A, 2 pole, 3 HP at 575 VAC, single phase, toggle operated, red 115 VAC indicator, NEMA 4, two conduit” Cancel reply	
				Related products
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
					Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open				
			Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
					Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open				
			Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
					Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm				
			Vacuum switch 9016G – adjustable scale – 2 thresholds – Set 0 to 23.8 InHg
					Vacuum switch 9016G - adjustable scale - 2 thresholds - Set 0 to 23.8 InHg				
			TeSys Deca thermal overload relays – 23…32 A – class 10A
					TeSys Deca thermal overload relays - 23...32 A - class 10A				
			Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
					Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts				
			communication module Profibus DP V1, Altivar, 12Mbps, 1 female SUB D9 connector
					communication module Profibus DP V1, Altivar, 12Mbps, 1 female SUB D9 connector				
			
		
								
								
		
		
		
		
		
		
		
		
Reviews