Surgelogicâ„¢ EBA replacement modules surge protective devices are apart of modular brick parallel device. The EBA device has multi-stage suppression circuits consisting of field-proven, fast-acting metal oxide varistors (MOVs). These systems provide suppression, enchanced EFI/RFI filtering for all critical modes inside electrical equipment, and shorter lead lengths with superior SPD performance. This surge protection device is 3 phase, 4-wire + ground, 240/120 V, 120 kA surge current per phase, and short circuit current rating of 200 kA. They provide better performance with a diagnostic interface with push to test switches, red and green status LEDs, module status LEDs per mode, dry contacts, audible alarm with disable switch, and a surge counter. The device is engineered to UL 489 11th Edition, type 2 SPD and complies with UL 96A 12th Edition Master Label for Lightning Protection Systems.
Surge protection module, Surgelogic, MA, 120kA, 480Y/277VAC, 3 phase, 4 wire, SPD type 2
Surge protection module, Surgelogic, MA, 120kA, 480Y/277VAC, 3 phase, 4 wire, SPD type 2
SKU: 2925826
Category: Circuit Breakers
Reviews (0)
Be the first to review “Surge protection module, Surgelogic, MA, 120kA, 480Y/277VAC, 3 phase, 4 wire, SPD type 2” Cancel reply
Related products
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT Q, 200A, 3 pole, 240VAC, 65kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT Q, 200A, 3 pole, 240VAC, 65kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, AC
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, AC
Circuit breaker, PowerPacT H, 20A, 2 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, AC
Circuit breaker, PowerPacT H, 20A, 2 pole, 600VAC, 25kA, I-Line, thermal magnetic, 80%, AC
Miniature circuit breaker (MCB), Multi9 C60SP, 4P, 63A, C curve, 5kA (UL1077), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60SP, 4P, 63A, C curve, 5kA (UL1077), 10kA (IEC/EN 60947-2)
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker accessory, PowerPacT J, terminal nut, for busbar, tap M8, CE standard, qty 2
Circuit breaker accessory, PowerPacT J, terminal nut, for busbar, tap M8, CE standard, qty 2
Reviews