This RS485 shielded cable is used to connect 2 safe communication expansion modules. It is designed to link two safe communication modules, in order to create decentralized cabinets of remote IO. This cable figures 2 pairs of twisted conductors with shielding with flying lead connection. RS485 serial interface shielded cables are used between the Bus expansion communication modules to create up to six decentralized safety-related islands with a maximum of 50 meters between each island. It weighs 2.3kg. It measures 25m. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
RS485 shielded cable to build safety islands with safe com. modules – 25 m
RS485 shielded cable to build safety islands with safe com. modules – 25 m
SKU: 172549399
Category: Automation & Control
Reviews (0)
Be the first to review “RS485 shielded cable to build safety islands with safe com. modules – 25 m” Cancel reply
Related products
Vacuum switch 9016G – adjustable scale – 2 thresholds – Set 0 to 23.8 InHg
Vacuum switch 9016G - adjustable scale - 2 thresholds - Set 0 to 23.8 InHg
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24…240VAC/DC, 1/2″
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24...240VAC/DC, 1/2"
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Harmony XB5S, Protective cover for Biometric switch
Harmony XB5S, Protective cover for Biometric switch
Reviews
There are no reviews yet.