HomeNEMA Contactors & Starters NEMA Starter, Type S, reversing, horizontal, Size 2, 45A, 25 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 240 VAC coil, NEMA 12
Previous product
primary_image
Harmony XB4, Joystick controller head, plastic, Ø22, 4 directions, spring return
Back to products
Next product
primary_image
Photoelectric sensors XU, XUB, emitter, 90°, 12...24 VDC, M12

NEMA Starter, Type S, reversing, horizontal, Size 2, 45A, 25 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 240 VAC coil, NEMA 12

NEMA Starter, Type S, reversing, horizontal, Size 2, 45A, 25 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 240 VAC coil, NEMA 12

SKU: 1430325 Category: NEMA Contactors & Starters
Share
Facebook Twitter Pinterest linkedin Telegram
  • Description
  • Reviews (0)
Description

Type S NEMA reversing magnetic starters are used for full voltage starting, stopping, and reversing AC squirrel cage motors. NEMA 8736 reversing starters are available in NEMA Sizes 00 to 7 and have ratings up to 810 amperes. NEMA reversing starters consist of two 8502S NEMA contactors that are mechanically and electrically interlocked and an overload relay. Sizes 0-5 reversing starters are available in either horizontal or vertical arrangements. This reversing starter is arranged horizontally. This 3 pole NEMA Size 2 reversing starter has an 45 ampere rating. This three phase NEMA Size 2 reversing starter has 10 HP at 200 VAC, 15 HP at 230 VAC and 25 HP at 460 and 575 VAC ratings. This reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 220/240 VAC 50/60 Hz operating coil wired for common control. This NEMA reversing starter is in painted sheet steel NEMA 12/3R dusttight and driptight industrial use enclosure. This enclosure is 16.00 inches tall, 14.88 inches wide and 7.88 inches deep. A wide variety of accessories are available for Type S starters. Type S reversing NEMA motor starters are UL listed and CSA certified.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “NEMA Starter, Type S, reversing, horizontal, Size 2, 45A, 25 HP at 575 VAC, 5 kA SSCR, 3 phase, 3 pole, melting alloy overload, 240 VAC coil, NEMA 12” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

primary_image
Close

IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 208VAC 50/60Hz coil, open style

IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 208VAC 50/60Hz coil, open style
Quick view
primary_image
Close

IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style

IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 2 NO and 2 NC, 24VDC coil, open style
Quick view
primary_image
Close

IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VAC 50/60Hz coil, open style

IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VAC 50/60Hz coil, open style
Quick view
primary_image
Close

IEC contactor, TeSys Deca Green, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60VAC/VDC coil, open

IEC contactor, TeSys Deca Green, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60VAC/VDC coil, open
Quick view
primary_image
Close

NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 3 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 12

NEMA Motor Starter, Type S, nonreversing, Size 1, 27A, 3 HP at 230 VAC, 5 kA SCCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 12
Quick view
primary_image
Close

TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 9 A – 240 V AC coil

TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 240 V AC coil
Quick view
primary_image
Close

TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 630 A – coil 415 V AC

TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 415 V AC
Quick view
primary_image
Close

NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 25 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 600 VAC coil, open

NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 25 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 600 VAC coil, open
Quick view
  • LOCATION

    305 Clearview Rd, Suite 2
    Edison, NJ 08837

  • PHONE

    (201)617-5800 |

    FAX

    (201)617-5557

  • EMAIL

    sales@cuny.biz

Contact

201-617-5800

Hours of Operations: 6:30am - 6pm
Site Map
  • Home
  • About Us
  • Careers
  • Contact Us
Product Line
  • Contractor Supplies
  • Machine Control
  • Electrical Enclosures
  • Distribution
  • Circuit Protection
  • Automation
Contact Us Copyright 2020 Cuny & Guerber, Inc All Rights Reserved
  • Home
  • About Us
    • History
    • Capabilities
  • Product Line
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Scroll To Top