PowerPact™ R-frame electronic trip molded case circuit breakers are designed to protect electrical systems from damage caused by overloads, short circuits, and ground faults. All circuit breakers are designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent. Electronic trip molded case circuit breakers use an electronic trip system to signal the circuit breaker to open automatically. The PowerPact R-frame (3000A frame size) circuit breakers are dual rated to UL489 and IEC 60947-2. P-frame, R-frame molded case circuit breakers are available with either a basic ET 1.0I electronic trip system or with a more advanced Micrologic™ trip system. Electronic trip motor circuit protectors (trip system ET 1.0M), which trip on short circuit only, and automatic molded case switches, which trip at a predetermined self-protection level only, are also available for special applications. This PowerPact R, circuit breaker has a rated currrent of 2000A and a rated operational current of 600VAC with a breaking capacity of 65 kA@600VAC. This 3-pole breaker is a unit mount and has a continuous current rating of 100 %. This breaker has an electronic trip unit technology and a Micrologic 3.0 trip unit. This product complys to UL listed, CSA & IEC standards. Dimensions forThis product are 16.24 in (H), 16.53 in (W), 14.49 in (D). This product comes with an 18 month warranty.
POWERPACT R-FRAME, MOLDED CASE CIRCUIT BREAKER, 600V, 2000A, 3P, 65kA
POWERPACT R-FRAME, MOLDED CASE CIRCUIT BREAKER, 600V, 2000A, 3P, 65kA
SKU: 8934837
Category: Power Distribution
Reviews (0)
Be the first to review “POWERPACT R-FRAME, MOLDED CASE CIRCUIT BREAKER, 600V, 2000A, 3P, 65kA” Cancel reply
Related products
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Ring tongue terminal connections kit – for C60 upstream/downstream – set of 2
Ring tongue terminal connections kit - for C60 upstream/downstream - set of 2
Multi 9 – C60 UL489 – MCB – 1P – 20 A – C Curve – 277 V – 10 kA – tunnel term
Multi 9 - C60 UL489 - MCB - 1P - 20 A - C Curve - 277 V - 10 kA - tunnel term
Multi 9 – C60 UL489 – MCB – 1P – 6 A – D Curve – 120 V – 10 kA – tunnel term
Multi 9 - C60 UL489 - MCB - 1P - 6 A - D Curve - 120 V - 10 kA - tunnel term
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Reviews
There are no reviews yet.