PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn’t have that interchangeability. This circuit breaker has a Micrologic Interchangeable Harmonic Trip with a 6.0H trip unit and an LSIG function with Modbus communication. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. The circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 6.0H, 100%, modbus
Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 6.0H, 100%, modbus
SKU: 16943832
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 6.0H, 100%, modbus” Cancel reply
Related products
Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Multi 9 – C60 UL489 – MCB – 1P – 6 A – D Curve – 120 V – 10 kA – tunnel term
Multi 9 - C60 UL489 - MCB - 1P - 6 A - D Curve - 120 V - 10 kA - tunnel term
Transformer disconnect, 2000VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 2000VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Ring tongue terminal connections kit – for C60 upstream/downstream – set of 2
Ring tongue terminal connections kit - for C60 upstream/downstream - set of 2
Multi 9 – C60 UL489 – MCB – 1P – 20 A – C Curve – 277 V – 10 kA – tunnel term
Multi 9 - C60 UL489 - MCB - 1P - 20 A - C Curve - 277 V - 10 kA - tunnel term
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Reviews
There are no reviews yet.