PowerPacTÂ Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has lugs on the load side and terminal nuts on the line side. It has studs on the load end with no nuts and washers. This PowerPacT Q, 125A, 3 pole, circuit breaker has an interrupting rating of 10kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
Circuit breaker, PowerPacT Q, 125A, 3 pole, 240VAC, 10kA, lugs, thermal magnetic, 80%, top of panel
Circuit breaker, PowerPacT Q, 125A, 3 pole, 240VAC, 10kA, lugs, thermal magnetic, 80%, top of panel
SKU: 8944551
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT Q, 125A, 3 pole, 240VAC, 10kA, lugs, thermal magnetic, 80%, top of panel” Cancel reply
Related products
Rectangular sensor L2 type, VigiPacT, 470mmx160mm, 3200A
Rectangular sensor L2 type, VigiPacT, 470mmx160mm, 3200A
Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Straight length, I-Line Busway, 1000A, 600VAC, 3 phase, 3 wire, integral ground bus, Al, plug-in, 10ft
Straight length, I-Line Busway, 1000A, 600VAC, 3 phase, 3 wire, integral ground bus, Al, plug-in, 10ft
Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A
Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A
Reviews
There are no reviews yet.