The PowerPact® Q-frame line of circuit breakers include QB, QD, QG and QJ molded case circuit breakers and QB automatic switches. They are rated 240 Vac, 250 A max. and are available in lug or bus-connected unit-mount constructions, or I-Line® group-mounted construction. PowerPact Q-frame circuit breakers are rated for 240 Vac (208Y/120 Vac for 3-pole 100 kA) and are available with UL® Listed interruption ratings from 10 kA to 100 kA. Unit-mount circuit breakers are available with lugs on both ends for cabled applications or with mounting studs for bus-mounted applications. These circuit breakers may be mounted in individual enclosures, metering devices, panelboards or switchboards. The PowerPact Q-frame circuit breaker is a direct replacement for the Q2 Series device. This PowerPact Q, circuit breaker is a 2-pole and has a rated current of 80A. This breaker has a breaking capacity of 25kA@240VAC and has a continuous currrent rating of 80 %. This I-Lineed breaker has a thermal-magnetic trip unit technology with a magnetic hold current of 1000 A and a magnetic tripping current of 1800A. Dimensions for this product are 6.47 in (H), 3.00 in (W), 3.93 in (D). This product complys to UL listed, CSA & IEC standards.
Circuit breaker, PowerPacT Q, 80A, 2 pole, 240VAC, 25kA, I-Line, thermal magnetic, 80%, AC
Circuit breaker, PowerPacT Q, 80A, 2 pole, 240VAC, 25kA, I-Line, thermal magnetic, 80%, AC
SKU: 15226045
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT Q, 80A, 2 pole, 240VAC, 25kA, I-Line, thermal magnetic, 80%, AC” Cancel reply
Related products
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Circuit breaker accessory, PowerPacT J, rear connection kit, 3 pole, mixed, 4x short, 2x covers
Circuit breaker accessory, PowerPacT J, rear connection kit, 3 pole, mixed, 4x short, 2x covers
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic

Reviews
There are no reviews yet.