The coil can be easily replaced in a Type S contactor or starter. By changing out the coil, the contactor or starter can be used in different control circuit voltage applications. This will also save the cost of a whole new contactor or starter if the coil were to fail. This coil is used in an 8502SE contactor, an 8536SE starter, an 8903SQ lighting contactor or an 8910DPA12 definite purpose contactor. This coil is rated for 220/240 VAC 50/60 Hz. The inrush power of this coil is 700 VA. It has an average sealed consumption of 46 VA. This coil has a height of 73 mm, a width of 65 mm and a depth of 53.2 mm. Coil is fully encapsulated to protect it. Coil has screw clamp connections.
NEMA Motor Starter, Type S, replacement coil, 220/240VAC 50/60Hz, 2 or 3 pole, NEMA size 3 starter and 8903SQ lighting
NEMA Motor Starter, Type S, replacement coil, 220/240VAC 50/60Hz, 2 or 3 pole, NEMA size 3 starter and 8903SQ lighting
SKU: 172554830
Category: Automation & Control
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, replacement coil, 220/240VAC 50/60Hz, 2 or 3 pole, NEMA size 3 starter and 8903SQ lighting” Cancel reply
Related products
Modular box PC, Harmony iPC, HMIBM Performance DC Base unit 8 GB 4 slots
Modular box PC, Harmony iPC, HMIBM Performance DC Base unit 8 GB 4 slots
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Vacuum switch 9016G – adjustable scale – 2 thresholds – Set 0 to 23.8 InHg
Vacuum switch 9016G - adjustable scale - 2 thresholds - Set 0 to 23.8 InHg
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
TeSys K reversing contactor – 3P – AC-3 <= 440 V 9 A – 1 NC – 24 V AC coil
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil
Reviews
There are no reviews yet.