Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 0 non-reversing starter has an 18 ampere rating. NEMA Size 0 motor starters have 3 phase ratings of 3 HP at 200 and 230 VAC and 5 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 6A to 18A range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 220/240 VAC 50/60 Hz operating coil wired for common control. This NEMA starter is an open device without an enclosure. This starter is 6.77 inches tall, 4.52 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 240 VAC coil, open
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 240 VAC coil, open
SKU: 172543359
Category: Automation & Control
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 240 VAC coil, open” Cancel reply
Related products
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Harmony XB5S, Protective cover for Biometric switch
Harmony XB5S, Protective cover for Biometric switch
interface plug-in relay, Harmony electromechanical relays, 12A, 1CO, 48V AC
interface plug-in relay, Harmony electromechanical relays, 12A, 1CO, 48V AC
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Vacuum switch 9016G – adjustable scale – 2 thresholds – Set 0 to 23.8 InHg
Vacuum switch 9016G - adjustable scale - 2 thresholds - Set 0 to 23.8 InHg
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
Reviews
There are no reviews yet.