Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 0 non-reversing starter has an 18 ampere rating. NEMA Size 0 motor starters have 3 phase ratings of 3 HP at 200 and 230 VAC and 5 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This NEMA starter is in a NEMA 4 & 4X brushed stainless steel watertight and dusttight enclosure. This enclosure is 13.19 inches tall, 6.38 inches wide and 7.81 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 4/4X
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 4/4X
SKU: 172542835
Category: Automation & Control
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 120 VAC coil, NEMA 4/4X” Cancel reply
Related products
Modular box PC, Harmony iPC, HMIBM Performance DC Base unit 8 GB 4 slots
Modular box PC, Harmony iPC, HMIBM Performance DC Base unit 8 GB 4 slots
communication module Profibus DP V1, Altivar, 12Mbps, 1 female SUB D9 connector
communication module Profibus DP V1, Altivar, 12Mbps, 1 female SUB D9 connector
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21

Reviews
There are no reviews yet.