This Multi 9 C60 UL489 is a low voltage miniature circuit breaker (MCB). It is a 2P circuit-breaker with 2 protected poles, 7A rated current and D tripping curve. It can be mounted on DIN rail for modular installation. As circuit-breaker, its breaking capacity, according to IEC/EN 60947-2, is 20kA at 230VAC and 10kA at 400VAC. This circuit-breaker offers a protection of circuits against overcurrent according to UL 489. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. It becomes IP40 once in modular enclosure. its fast closing mechanism improves its service life. The trip-free mechanism allows the contacts to not be held in the on position when the device is tripped automatically. The green mechanical indication guarantees the physical opening of the contacts to allow downstream maintenance.
Multi 9 – C60 UL489 – MCB – 2P – 7 A – D Curve – 240 V – 10 kA – tunnel term
Multi 9 – C60 UL489 – MCB – 2P – 7 A – D Curve – 240 V – 10 kA – tunnel term
	
			
		SKU: 1268982
	
	Category: Power Distribution
	
	
							
											
				Reviews (0)
				
					
						
							
	
			
					
		
	
	
						
					
				
			
					
		Be the first to review “Multi 9 – C60 UL489 – MCB – 2P – 7 A – D Curve – 240 V – 10 kA – tunnel term” Cancel reply	
				Related products
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
					Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB				
			Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
					Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic				
			Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
					Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term				
			Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
					Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches				
			EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
					EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA				
			Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
					Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise				
			Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
					Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC				
			Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
					Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A				
			 
		
 
								 
								 
		 
		 
		 
		 
		
Reviews
There are no reviews yet.