Square D™ EZ Meter-Pak™ devices are the industry choice, providing better solutions to meet more multi-unit construction needs than any other line in the industry. EZM Busway tap devices have been designed with space savings in mind so that they not only meet challenging job requirements, but the compact footprint also makes them easier to handle and install. This branch unit has a current rating of 225 A and a bus bar rating of 1200 A. This product is suitable for use as service equipment and supplied with ringed, no bypass, 4 jaw, 1 phase IN meter socket. It has provisions for mounting tenant QB, QD, QG, QJ circuit breakers to feed downstream type QO/HOM load centers or type NQOD panelboards. Five position meter breaker units can be connected in any combination, providing a solution for any size application. Unique field phase-balancing allows easy on-site changing of phase-balancing (standard on all 3 PH IN-1 PH OUT units). Visi-Tite® nut eliminates the need for time-consuming torque readings when connecting devices. External mounting channels permits immediate installation with no disassembly or adjustment required.
Branch unit, EZ Meter-Pak, 225A, 5 sockets, 120/240VAC, no bypass, ringless, 1200A Cu busbar
Branch unit, EZ Meter-Pak, 225A, 5 sockets, 120/240VAC, no bypass, ringless, 1200A Cu busbar
SKU: 16946351
Category: Power Distribution
Reviews (0)
Be the first to review “Branch unit, EZ Meter-Pak, 225A, 5 sockets, 120/240VAC, no bypass, ringless, 1200A Cu busbar” Cancel reply
Related products
Transformer, Type T, industrial control, 25VA, 1 phase, 240x480V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 25VA, 1 phase, 240x480V primary, 120V secondary, 55C rise
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Multi 9 – C60 UL489 – MCB – 1P – 20 A – C Curve – 277 V – 10 kA – tunnel term
Multi 9 - C60 UL489 - MCB - 1P - 20 A - C Curve - 277 V - 10 kA - tunnel term
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Meter socket, ringless, 1 phase, 3 wire, 8 jaws, solid top, no bypass, no jaw release
Meter socket, ringless, 1 phase, 3 wire, 8 jaws, solid top, no bypass, no jaw release
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Reviews
There are no reviews yet.