PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn’t have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 5.0A trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 250A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT P, 250A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.0A, 100%, ABC
Circuit breaker, PowerPacT P, 250A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.0A, 100%, ABC
SKU: 16942062
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT P, 250A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.0A, 100%, ABC” Cancel reply
Related products
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT R, 1600A, 3 pole, 600VAC, 50kA, busbar, Micrologic 5.0H, 80%, modbus
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
Reviews
There are no reviews yet.