2510M manual motor starters are designed for manual On Off control for small motors. This three pole starter is rated for 7.5 HP at 230 VAC and 10 HP at 460 VAC three phase motors. This starter is NEMA M-1 rated. The proper thermal unit must be selected and ordered separately to provide proper overload protection for the motor. 2510M manual starters can be ordered in a variety of enclosure types. This device is in a surface mount NEMA 4 and 4X watertight enclosure. Enclosure is made of brushed stainless steel. Enclosure as a provision to allow padlocking of this device. 2510M manual starters are UL listed and CSA certified. This enclosure has one 0.75 inch conduit entry on the bottom and one on the top. Enclosure is 10.92 inches tall, 5.78 inches wide and 5.76 inches deep. A toggle handle is used to turn the manual switch on and off. The toggle handle can be padlocked in the off or stop position. 2510M integral horsepower starters are UL listed and CSA certified.
Manual starter, integral horsepower, NEMA M1, 600VAC, 3 pole, 10HP at 380/575VAC, 3 phase, no indicator, NEMA 4/4X
Manual starter, integral horsepower, NEMA M1, 600VAC, 3 pole, 10HP at 380/575VAC, 3 phase, no indicator, NEMA 4/4X
SKU: 172568739
Category: Automation & Control
Reviews (0)
Be the first to review “Manual starter, integral horsepower, NEMA M1, 600VAC, 3 pole, 10HP at 380/575VAC, 3 phase, no indicator, NEMA 4/4X” Cancel reply
Related products
Harmony XB5S, Protective cover for Biometric switch
Harmony XB5S, Protective cover for Biometric switch
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24…240VAC/DC, 1/2″
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24...240VAC/DC, 1/2"
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Safety light curtain type 4, Telemecanique Safety light curtains XUSL, XUSL Body protection, Std sensing range, 3 Beams, Hp = 810 mm
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 30A, 2 pole, 110/120VAC 50/60Hz coil, open
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open

Reviews
There are no reviews yet.