QO generator panels are for the manual transfer from utility to generator power. QO generator panels are for back-up power applications. This sub-panel connects directly to the main load center and provides four single pole spaces that will accommodate up to eight circuits dedicated for back-up power. This QO generator panel uses two factory installed, two pole QO circuit breakers. One is fed by the utility, while the second circuit breaker is back-fed to the back-up power source, such as a generator. Power source switching is easy. Simply turn the main power breaker to the “OFF” position and then turn the generator fed breaker to the “ON” position. A factory installed mechanical interlock prevents both main breakers being in the “ON” position at the same time. This manual transfer equipment kit is used secure two 2 pole circuit breakers to left side of interior when used as back-fed mains. A QO2DTI kit is included for back-up power supply applications. This kit is used on Series S01 and S02 100A to 125A single phase convertible main load centers.
Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side
Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side
SKU: 172549198
Category: Power Distribution
Reviews (0)
Be the first to review “Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side” Cancel reply
Related products
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 25A, 3 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB

Reviews
There are no reviews yet.