QO generator panels are for the manual transfer from utility to generator power. QO generator panels are for back-up power applications. This sub-panel connects directly to the main load center and provides four single pole spaces that will accommodate up to eight circuits dedicated for back-up power. This QO generator panel uses two factory installed, two pole QO circuit breakers. One is fed by the utility, while the second circuit breaker is back-fed to the back-up power source, such as a generator. Power source switching is easy. Simply turn the main power breaker to the “OFF” position and then turn the generator fed breaker to the “ON” position. A factory installed mechanical interlock prevents both main breakers being in the “ON” position at the same time. This manual transfer equipment kit is used secure two 2 pole circuit breakers to left side of interior when used as back-fed mains. A QO2DTI kit is included for back-up power supply applications. This kit is used on Series S01 and S02 100A to 125A single phase convertible main load centers.
Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side
Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side
SKU: 172549198
Category: Power Distribution
Reviews (0)
Be the first to review “Load center accessory, QO, manual transfer kit, 1 phase, 100A to 125A, for convertible main load centers, left side” Cancel reply
Related products
Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Reviews
There are no reviews yet.