The PowerPact™ H-, J-, and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. L-frame circuit breakers are available with MICROLOGIC electronic trip units only. The amperage ratings of the thermal trip elements are calibrated at 104°F (40°C) free air ambient temperature. Circuit breakers rated for 100% operation are available but require specially-designed enclosures and 194°F (90°C) rated wire. Devices with the MICROLOGIC electronic trip unit provide adjustable protection settings for greater system flexibility In addition to electronic protection, MICROLOGIC trip units allow users to monitor both energy and power. PowerPact H-, J-, and L-frame circuit breakers offer high performance and a wide range of interchangeable trip units to protect most applications. Electronic trip units provide highly accurate protection with wide setting ranges and can integrate measurement, metering and communication functions. This PowerPact circuit breaker, is a 350A, and is a 3-pole,with a breaking capacity of 35kA@480VAC rated operatiuonal voltage. With a magnetic hold current of 1750A and a magnetic tripping current of 3500A. This breaker has a thermal-magnetic trip unit technology. This unit mount breaker copmplies to UL, CSA standards. Dinemsions for this product are 12.5 in (H), 6 in (W), 4 in (D), and an ambient temperature rating of 40 °C.
Circuit breaker, LH, I-Line mount, 350A, 3 pole, 25kA, 600VAC, thermal magnetic
Circuit breaker, LH, I-Line mount, 350A, 3 pole, 25kA, 600VAC, thermal magnetic
SKU: 1283941
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, LH, I-Line mount, 350A, 3 pole, 25kA, 600VAC, thermal magnetic” Cancel reply
Related products
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Circuit breaker, PowerPacT B, 90A, 3 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%, control wire ON end
Circuit breaker, PowerPacT B, 90A, 3 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%, control wire ON end
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 150A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A
Circuit breaker, PowerPacT H, 125A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT H, 125A, 3 pole, 600VAC, 18kA, lugs, thermal magnetic, 80%
Reviews
There are no reviews yet.