Individual Meter Sockets are available for single or three phase with a 600 VAC maximum. These individual meter sockets can be with and without horn or lever bypass. The sockets have a 10 kA short circuit current rating as standard but could have a higher rating with utility approval. Units are supplied with a bonded neutral. Units are supplied with a hub opening in top end wall which requires the use of a bolt on hub or a closing plate. This ringless meter socket has four jaws with lever bypass and jaw release. This meter socket is for single phase 3 wire systems up to 600 VAC. This meter socket has a 200 A rating. This unit must be fed from an overhead service. This unit has a NEMA 3R surface mounting enclosure that is 19.00 inches tall, 10.50 inches wide and 4.94 inches deep. The main lugs, the load lugs and the neutral lug will accept one 6 AWG to 350 kcmil copper or aluminum wire. The ground will accept 14 AWG to 2 AWG copper or aluminum wire. This individual meter socket is UL Listed.
Individual meter socket, ringless socket, lever bypass, 4 jaws no release, OH, 200 A, up to 600 VAC single phase 3W
Individual meter socket, ringless socket, lever bypass, 4 jaws no release, OH, 200 A, up to 600 VAC single phase 3W
SKU: 14731138
Category: Power Distribution
Reviews (0)
Be the first to review “Individual meter socket, ringless socket, lever bypass, 4 jaws no release, OH, 200 A, up to 600 VAC single phase 3W” Cancel reply
Related products
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)

Reviews
There are no reviews yet.