Square D LA molded case circuit breakers provide thermal magnetic protection. Their primary function is automatic opening of a circuit under overload or short circuit conditions or manual opening. LA circuit breakers contain thermal (overload) and magnetic (short circuit) sensing elements in each pole. Push-to-Trip allows the circuit breaker to be manually tripped without exposure to live parts. This Square D LA molded case circuit breaker is a 2 pole unit mount breaker, 400A and 600VAC. The thermal magnetic circuit breaker has an interrupting rating of 22kA for 600VAC and 10kA for 250VDC. The circuit breaker WB suffix indicates a walking beam interlock system. LA breakers are UL 489, CSA, IEC certified.
Circuit breaker, LA, 400A, 2 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, walking beam
Circuit breaker, LA, 400A, 2 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, walking beam
SKU: 9014070
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker, LA, 400A, 2 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, walking beam” Cancel reply
Related products
Mini CB, QO, 50 A, 1P, 120/240 V, 10 kA, Bolt on, 50Deg
Mini CB, QO, 50 A, 1P, 120/240 V, 10 kA, Bolt on, 50Deg
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 50kA, lugs, magnetic
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 50kA, lugs, magnetic
Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0H, 80%, ABC, modbus
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 18kA, I-Line, thermal magnetic, 80%, A
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 15A, 3 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, ABC
Reviews
There are no reviews yet.