Square D LA molded case circuit breakers provide thermal magnetic protection. Their primary function is automatic opening of a circuit under overload or short circuit conditions or manual opening. LA circuit breakers contain thermal (overload) and magnetic (short circuit) sensing elements in each pole. Push-to-Trip allows the circuit breaker to be manually tripped without exposure to live parts. This Square D LA molded case circuit breaker is a 3 pole unit mount breaker, 300A and 600VAC. The thermal magnetic circuit breaker has an interrupting rating of 22kA for 600VAC and 10kA for 250VDC. The circuit breaker suffix 1027 indicates undervoltage release. LA breakers are UL 489, CSA, IEC certified.
Circuit breaker, LA, 300A, 3 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, undervoltage release
Circuit breaker, LA, 300A, 3 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, undervoltage release
SKU: 9040832
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker, LA, 300A, 3 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, undervoltage release” Cancel reply
Related products
Miniature circuit breaker (MCB), Multi9 C60N, 4P, 4A, C curve, 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60N, 4P, 4A, C curve, 10kA (IEC/EN 60947-2)
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker, PowerPacT H, 15A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Mini circuit breaker, QO, 20A, 2 pole, 120/240VAC, 10kA, bolt on, AC shunt, ring
Mini circuit breaker, QO, 20A, 2 pole, 120/240VAC, 10kA, bolt on, AC shunt, ring
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Circuit breaker, PowerPacT M, 400A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT M, 400A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT B, 20A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 20A, 1 pole, 600Y/347VAC, 25kA, I-Line, thermal magnetic, 80%, C
Reviews
There are no reviews yet.