Facebook Twitter Pinterest linkedin Telegram
Cuny & Guerber Cuny & Guerber
  • Home
  • Events
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Menu
Cuny & Guerber
primary_image
Click to enlarge
HomeTransformers DOE 2016 LV XFMR, 3 Phase, 225kVA, 480 Delta-240 Delta, AL,
Previous product
primary_image
MOLDED CASE CIRCUIT BREAKER 600V 600A
Back to products
Next product
Placeholder
TeSys K reversing contactor - 3P - AC-3 <= 440 V 9 A - 1 NC - 24 V AC coil

DOE 2016 LV XFMR, 3 Phase, 225kVA, 480 Delta-240 Delta, AL,

DOE 2016 LV XFMR, 3 Phase, 225kVA, 480 Delta-240 Delta, AL,

SKU: 16796031 Category: Transformers
Share
Facebook Twitter Pinterest linkedin Telegram
  • Description
  • Reviews (0)
Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 225kVA, 480V primary (three wire), 240V secondary (three wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.94% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of 1/2 inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer’s open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “DOE 2016 LV XFMR, 3 Phase, 225kVA, 480 Delta-240 Delta, AL,” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

primary_image
Close

TRFMR CONTROL 300VA MULTIPLEVOLTAGES

TRFMR CONTROL 300VA MULTIPLEVOLTAGES
Quick view
Placeholder
Close

75KVA TP1 240X480V-120/240V

75KVA TP1 240X480V-120/240V
Quick view
Placeholder
Close

Transformer Dry Type 500kVA 600D208Y120

Transformer Dry Type 500kVA 600D208Y120
Quick view
primary_image
Close

TRFMR CONTROL 50VA 208/230/460V-115V

TRFMR CONTROL 50VA 208/230/460V-115V
Quick view
Placeholder
Close

TRFMR CONTROL 1000VA MULTIPLEVOLTAGES

TRFMR CONTROL 1000VA MULTIPLEVOLTAGES
Quick view
Placeholder
Close

GENERAL PURPOSE CURRENT TRANSFORMER 150/1A

GENERAL PURPOSE CURRENT TRANSFORMER 150/1A
Quick view
Placeholder
Close

TRANSFORMER CURRENT 800:5 6-7/8 I.D.

TRANSFORMER CURRENT 800:5 6-7/8 I.D.
Quick view
Placeholder
Close

DOE 2016 LV XFMR, 3 Phase, K-13, 500kVA, 480 Delta-208Y/120, AL,

DOE 2016 LV XFMR, 3 Phase, K-13, 500kVA, 480 Delta-208Y/120, AL,
Quick view
  • LOCATION

    305 Clearview Rd, Suite 2
    Edison, NJ 08837

  • PHONE

    (201)617-5800 |

    FAX

    (201)617-5557

  • EMAIL

    sales@cuny.biz

Contact

201-617-5800

Hours of Operations: Counter Hours: 6:30am - 5pm Office Hours: 8am - 5pm Monday - Friday
Product Line
  • Contractor Supplies
  • Machine Control
  • Electrical Enclosures
  • Distribution
  • Circuit Protection
  • Automation
Contact Us Copyright 2020 Cuny & Guerber, Inc All Rights Reserved
  • Home
  • Events
  • About Us
    • History
    • Capabilities
  • Product Lines
    • Automation
    • Circuit Protection
    • Distribution
    • Electrical Enclosures
    • Machine Control
    • Motor Control
    • Contractor Supplies
  • Schneider Catalog
  • Contact Us
    • Careers
Scroll To Top